Operation - Dustcontrol DC 5800 H Turbo EX Traduction Des Instructions De Service D'origine

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 41
3
Max. flow [m
/h]
Negative pressure, max. [kPa]
Power rating [W]
Fine filter, polyester, area [m
Efficiency, fine filter, EN 60335-2-69, Class M [%]
Filter area, HEPA filter [m
Efficiency, fine filter, EN 60335-2-69, Class H [%]
Filter classification, EN 1822-1
Sound level [dB(A)]
*/ Sound pressure level at 1.6 m height and 1 m distance according to DIN EN ISO 3744 in free field measurement at maximum
air flow.

Operation

Connection
Connect the machine to an electrical outlet with a voltage as per the machine's rating plate specifications. If using an extension
cord, it must be water-resistant.
CAUTION
The container is held in place by fasteners which means that a clamp must be placed on the machine's
grounding braid. This is ensured by aligning the opposite red arrow markings.
Emptying
The container underneath the cyclone should be emptied when about 2/3 full.
Be careful when releasing the fasteners – they can open with great force – especially when the material is heavy. Be aware that
emptying the container may pose a risk of explosion, i.e. that an explosive atmosphere may occur and that static charge may be
generated by the friction of the particles against the container. For appropriate measures, see CENELEC TR 50404.
When the container is to be emptied, the two fasteners must be carefully released, one at a time, to prevent dust from swirling up
unnecessarily. When the machine's container has been lowered, turn on the separator again so that any stuck particles are
sucked into the filter cyclone.
Carefully remove the filled sack from the edge of the container and immediately seal it tightly.
You must clean the filters before replacing the plastic bag. It should be replaced when the dust level is about 5 cm below the
discharge flap.
Fit a new plastic sack and place the opening carefully back over the edge of the container. Make sure that no creases are formed
and that the sack is not damaged. Then carefully install the tray under the separator and fasten the two hooks, turn off the
machine and once more secure the tray on the machine, make sure that the fastening hooks are located properly and check for
leakage.
16
2
]
2
]
DC 5800, Art.nr. 94269-B
DC 5800 H Turbo EX
470
28
4000
8,3
99,9
2,7
99,995
HEPA H13
<75

Publicité

Table des Matières
loading

Table des Matières