Problem
Cause
Motor runs, but no
Suction hose not connected.
suction.
Hose blocked.
The container is not properly
fitted.
Motor runs, but
Suction hose perforated.
poor suction.
Blocked filter.
Suction hose too long or
narrow.
Hose partially blocked.
Top of machine poorly fitted.
Dust trapped in cyclone.
Abnormal sound
from machine.
*) The motor protection must never be readjusted as it is set from the factory to protect against overheating.
The middle picture shows tripped motor protection.
EC Declaration of Conformity
We hereby declare that the DC 5800 Turbo EX is in conformity with the following directives and standards: 2006/42/EC,
2014/35/EU, 2014/30/EU, 2014/34/EU. The supplied connector is only intended for connection outside the zone. In case of
electrical connection inside the zone, the connector must be replaced by a version approved for the application. The machine
must not be used for explosives, unstable or self-igniting substances or dust with minimum ignition energy (MIE) < 3 mJ. No hot
or glowing particles may be sucked with the device. The serial number and year of manufacture are indicated on the rating plate
of the machine. The machine should also be marked:
Dustcontrol AB
Anna-Lena Berg / CEO
2019-05-07
20
Action
Connect hose.
Reverse or clean hose.
Fit the container.
Replace hose.
Clean or replace.
Replace hose.
Reverse or clean hose.
Adjust fitting.
Remove top and clean cyclone.
Book service.
Peter Söderling / Technical Manager
DC 5800, Art.nr. 94269-B