• Dimensioni: modulo da 6 unità
basso per guida DIN (fig. 2).
L'apparecchio può essere installa-
to, senza coprimorsetti, in scatole
munite di guida DIN (EN 50022).
Per le dimensioni di ingombro
vedere la fig. 2A.
Oppure può essere installato a
parete utilizzando la guida DIN in
dotazione ed applicando il copri-
morsetti.
Per le dimensioni di ingombro
vedere la fig. 2B.
GB INSTALLATION
INSTRUCTIONS
SELECTOR FOR INTERCOMS
VSE/300
Using the selector, different grou-
ps of intercom receivers (max. 10)
can be connected with the main
line of an X2 TECHNOLOGY
system or system 300 installation.
Connection between the VSE/300
selector and receivers is achieved
with a nonpolarized twisted pair.
The intercom system can also
work independently without con-
nection to an audio or video entry
control system.
Main functions
• Secrecy of speech
- Secrecy of speech between
intercom receivers and receivers
connected to the main line.
- Secrecy of speech between
communicating intercom receivers
and other intercom receivers not
involved in conversation.
• Calls
- Option of having all receivers
ring at the same time when a call
is made from the entry panel or the
doorbell pressed.
- Calls from the entry panel can be
programmed individually or by
group.
- Different call notes for entry
panel call, porter call, personal
door bell and intercom call.
- The call warning option can be
enabled to advise the user of a
call from the entry panel, porter or
front door during conversation.
- Telephone-type call ring lasts 30
sec.
• Busy warning
- All receivers are advised of busy
status by the LED.
- Busy status warning is also sent
to the main installation (entry
panels, porter).
• Call transfer
- An intercom receiver can tran-
sfer calls from the entry panel to
another intercom receiver.
- The receiver receiving the tran-
sferred call can, in turn, retransfer
it to another.
• Video signal distribution
- The VSE/300 selector can be
used to transfer video signals,
coming from the main line, to inter-
com monitors using the same twi-
sted pair used for connection.
- During a conversation between
intercoms, the user can opt to view
the image coming from the main
line following a call or self-connec-
tion to monitor the entrance.
• Programming intercom calls
- Intercom receivers are easily
associated with selector VSE/300
by pressing the relevant buttons
(max. 10).
- The same intercom call can be
assigned to a number of receivers
(max. 9).
• Special functions
- Buttons not used for intercom
calls may be used for auxiliary
functions with the aid of actuators.
- Using selector VSE/300, non-
intercom receivers can be added.
Function of each terminal (fig. 1)
Terminal block M1
12÷16 VAC 14÷18 VDC
power supply
bus input
B IN
from main line
Terminal block M2
bus output towards
B OUT
receivers
personal door bell
– ground
Programming
The selector VSE/300 program-
ming procedure must be perfor-
med once you have programmed
which calls from the entry panels
are to be associated with which
receivers.
1- Set selector VSE/300 to pro-
gramming mode by removing jum-
per SW1 (fig. 1);
2- Start with the receiver to be pro-
grammed and press the call button
(from 1 to 10) to be used to call it.
The receiver emits a sound three
times to confirm programming has
been completed successfully.
3- Repeat the procedure descri-
bed in point 2 for all receivers.
If there are any non-intercom
receivers, the selector must be
advised accordingly by pressing
button Aux 2.
4- Exit programming by refitting
jumper SW1.
Adding a receiver
When wanting to add a receiver to
the installation, selector VSE/300
must be reprogrammed.
Technical features
• Power supply: 12÷16 V AC
14÷18 V DC.
• Current demand: max. 850 mA.
• Line transmitting towards recei-
vers: nonpolarized twisted pair
(Z = 100Ω).
• Line connecting to main line:
non polarized twisted pair (Z =
100Ω).
• Doorbell: continuous 3 s ring.
• Intercom call note duration: 30 s.
• Maximum distances: 100 m
between selector and last recei-
ver connected to the system.
• Maximum number of selectors in
a
system
300
installation
(XA/300LR): 100.
• Maximum number of selectors in
a system X2 installation: 25.
• Working temperature range: 0
°C to +35 °C.
• Dimensions: low-profile 6-unit
module for installation on DIN
rail (fig. 2).
The unit can be installed, without
terminal covers, in boxes featuring
DIN rails (EN 50022).
See fig. 2A for overall dimensions.
Alternatively, they can be installed
on a wall using the DIN rail sup-
plied
and
applying
terminal
covers.
See fig. 2B for overall dimensions.
INSTALLATIONS-
D
ANLEITUNG
WÄHLSCHALTER FÜR INTER-
COM-ANLAGEN VSE/300
Durch den Wählschalter ist ein
Anschluss zwischen Gruppen von
Intercom-Innensprechstellen
(max. 10) und der Hauptleitung
einer Anlage des Systems X2
TECHNOLOGY oder des Systems
300 möglich.
Der Anschluss zwischen dem
Wählschalter VSE/300 und den
Innensprechstellen erfolgt über
eine ungepolte Telefonschleife.
Der Betrieb der Intercom-Anlage
kann auch autonom, und zwar
ohne den Anschluss an eine
Sprech- oder Videosprechanlage
erfolgen.
Hauptfunktionen
• Mithörsperre
- Mithörsperre zwischen Intercom-
Sprechstellen und Sprechstellen
mit Anschluss an die Hauptlei-
tung.
- Mithörsperre zwischen miteinan-
der
verbundenen
Intercom-
Sprechstellen und die anderen
nicht am Gespräch teilnehmenden
Intercom-Sprechstellen.
• Anrufe
- Alle Innensprechstellen können,
sobald
ein
Anruf
von
Außenstation und vom Treppen-
haus erfolgt, gleichzeitig klingeln.
- Die Anrufe von der Außenstation
sind einzeln oder gruppenweise
programmierbar.
- Rufunterscheidung
zwischen
Außenstation, Pförtnerstelle, Trep-
penhaus und Intercom-Anlage.
- Während des Gesprächs kann
die
Meldung
eines
dritten
Gesprächsteilnehmers von der
Außenstation, Pförtnerstelle und
dem Treppenhaus empfangen
werden.
- Rufton wie Telefonton, Dauer 30 s.
• Besetztzeichen
- Diese Leuchtanzeige wird an
alle Sprechstellen über eine LED
übertragen.
- Auch die Hauptanlage (Außen-
stationen, Pförtnerstelle) empfängt
das Besetztzeichen.
• Anrufumleitung
- Eine Intercom-Innensprechstelle
kann den Anruf von der Außen-
station auf eine andere Intercom-
Sprechstelle umleiten.
- Die Sprechstelle, die den umge-
leiteten Anruf erhält, kann ihrer-
seits den Anruf umleiten.
• Verteilung des Videosignals
- Durch den Wählschalter VSE/300
ist die Umleitung des von der
Hauptleitung stammenden Video-
signals zu den Intercom-Monitoren,
über die Benutzung derselben
Telefonschleife, möglich.
- Während
eines
Gesprächs kann das infolge eines
Anrufs oder einer Selbsteinschal-
tung von der Hauptleitung kom-
mende Videobild eingeblendet
werden.
• Programmierung der Intercom-
Anrufe
- Durch das Drücken der jeweili-
gen Tasten (max. 10) kann die
Intercom-Sprechstelle dem Wähl-
schalter VSE/300 mühelos zu-
geordnet werden.
- Derselbe Intercom-Anruf kann
mehreren Sprechstellen (max. 9)
zugeordnet werden.
• Sonderfunktionen
- Die nicht für Intercom-Anrufe
verwendeten Tasten können, mit-
tels Aktuatoren, für Sonderfunktio-
nen eingesetzt werden.
- Der Wählschalter VSE/300 ermö-
glicht
das
Hinzufügen
Sprechstellen,
die
Intercom-Anlage gehören.
Funktion der Klemmleisten (Abb. 1)
Klemmleiste M1
12÷16 VAC 14÷18 VDC
Stromversorgung
Buseingang von
B IN
der Hauptleitung
Klemmleiste M2
Busausgang zu den
B OUT
Innensprechstellen
Anruf vom Treppenhaus
– Masse
Programmierung
Die Programmierung des Wähl-
schalters VSE/300 muss nach der
Programmierung für die Zuord-
der
nung der Anrufe von den Außen-
stationen mit den Innensprech-
stellen durchgeführt werden.
1- Wählschalter
VSE/300
Programmierung einstellen und
dabei die Überbrückungsklemme
SW1 abnehmen (Abb. 1).
2- Sich vor die zu programmieren-
de Innensprechstelle stellen und
Ruftaste (von 1 bis 10), mit der
man den Anruf betätigen möchte,
drücken.
Der Dreiklang der Sprechstelle
bestätigt die erfolgte Program-
mierung.
3- Den im Punkt 2 beschriebenen
Vorgang für alle Sprechstellen
wiederholen.
Bei Innensprechstellen, die nicht
zu Intercom-Anlagen gehören, ist
der Wählschalter über deren
Anwesenheit zu informieren und
hierfür die Taste Aux 2 zu drücken.
4- Programmierung beenden und
Überbrückungsklemme SW1 wie-
der einsetzen.
Intercom-
von
nicht
zur
auf
3