AutoTect
mode
TM
Set the slide-switch function selector to the
AutoTect
feature automatically selects measurement function of DCV, ACV or
TM
Resistance (Ω) based on the input via the test leads.
• With no input, the meter displays "Auto" when it is ready.
• With no voltage signal but a resistance below 6MΩ is present, the meter
displays the resistance value. When below 25Ω (0.025kΩ) is present, the meter
also gives a continuity beep tone.
• When a signal above the threshold of +1.5 VDC, -1 VDC or 2 VAC up to the
rated 600V is present, the meter displays the voltage value in appropriate DC
or AC, whichever larger in peak magnitude.
• Overload-Alert Feature: When above rated 600V is present, the meter displays
"OL" with a warning beep tone for over-range indication. Disconnect the test
leads from the signal immediately to avoid hazards.