AC Voltage Detection - VolTect
At any function, press the EF (NCV) button momentarily to toggle to AC
Voltage Detection, VolTectTM. The meter displays "
strength is indicated as a series of bar-graph segments on the display plus
variable beep tones.
• Non-Contact EF-Detection (NCV): An antenna is located along the top of
the stationary jaw (See
surrounds current-carrying conductors. It is ideal for tracing live wiring
connections, locating wiring breakage and to distinguish between live or
earth connections.
• Probe-Contact EF-Detection: For more precise indication of live wires, such
as distinguishing between live and ground connections, use the Red (+) test
probe for direct contact measurements.
TM
symbol on the jaw), which detects electric field
9