Barcellona
English
17. 1 Draining the water
Install a floor drain with a slight slope to avoid:
unpleasant odours inside the cabinet
- dispersion of cooled air
- malfunction of the cabinet due to moisture
Procedure
- install a suitable siphon between the drain and the connection to ground
- hermetically seal the area of drainage to ground.
i
periodically check that hydraulic connections are perfectly efficient, contacting a qualified
installer.
18. Lighting
Internal lighting of the unit is obtained through fluorescent bulbs.
On request, the fluorescent bulbs can be replaced with LEDs.
CAUTION! Accidental breakage of bulbs. Injury. Contamination of the goods.
- wear the envisioned PPE
- cut off power supply to the cabinet
- remove all goods
- clean as indicated in section 22.4
- remove any trace of glass from the goods
- reload the cabinet with goods cleaned thoroughly
- restore electrical power supply.
19. Replace the bulbs
DANGER! Live parts. Electrocution.
REMOVE THE ELECTRIC POWER SUPPLY BEFORE ANY OPERATION!
Replace the bulbs with new, identical models
20. Maintenance and cleaning
DANGER! Live parts. Electrocution.
REMOVE THE ELECTRIC POWER SUPPLY BEFORE ANY OPERATION!
DO NOT wet, spray water or clean directly the electrical parts of the cabinet (fans, inte-
rior lighting, electrical cables etc. )
DO NOT touch the cabinet with wet or damp hands and feet.
CAUTION! Cold surfaces. Injuries, burning. Glass breakage.
Wait for the glass parts to reach room temperature.
DO NOT use hot water on the cold glass surfaces.
Protect the hands with work gloves.
i
The products will damage due to germs and bacteria.
Compliance with Hygiene Standards and the cold chain is indispensable to guarantee the
protection of consumer health.
The cleaning operations must include:
Step
Name
1
Washing
40
roughing, removal of approximately 97% of the dirt)
Description