2. Stop the air conditioner immediately is one of the following anomalies occurs.
Disconnect the electric power supply and contact the nearest after-sales assistance service.
Problem:
- the fuses blow frequently or the automatic switch intervenes often.
- Water or other objects have entered the air conditioner.
- the remote control does not function or functions anomalously.

4.4.1 - Malfunctioning

Do not try to repair the unit alone.
Malfunctioning
The unit will not start.
The unit does not cool or heat
the room well (only for cooling/
heating models), while air
escapes from the conditioner.
if the problem has not been solved, contact the local dealer or nearest after-sales assistance service.
Provide detailed information regarding malfunctioning and the unit model.
EN - 38
Cause
Current failure
the unit is disconnected from the
current.
a fuse has blown.
the remote control batteries may be
discharged.
the time set with the timer may not
be correct.
incorrect temperature setting.
The air filter is clogged.
the doors or windows are open.
the air inlet or outlet vents of the
indoor or outdoor units are blocked.
the compressor 3 minute protection
has activated.
the compressor is broken
there is too much or too little refrig-
erant in the system.
Gas or humidity entered the system.
there are too many heat sources
in the room (people, computer, etc.)
the "Silent" function is activate.
What must be done?
Wait for the current to be restored.
Check that the plug is inserted in the
wall socket.
replace the fuse.
replace the batteries.
Wait or annul the timer setting.
Set the temperature correctly. Consul
the "Using the remote control" chapter
for the procedure.
Clean the air filter.
Close the doors or windows.
first, remove the obstructions and
then re-start the unit.
Wait.
replace it.
Check for the presence of leaks
and/or recharge the system with
refrigerant.
evacuate and recharge the system
with new refrigerant.
reduce the quantity of heat sources
at a minimum.
the "Silent" function can reduce
the performance of the product by
reducing the operating frequency.
Disable the "Silent" function.