TIG comfort-stop
function
(continued)
Fig.9
Downslope:
The downslope is dependent upon the welding amperage that has been selected, and
cannot be adjusted.
-
-
Example: Where an average (i.e. medium) welding amperage of 70 A has been selec-
ted, the downslope will be 1.5 seconds long.
Gas post-flow time:
The gas post-flow time is dependent upon the welding amperage that has been selec-
ted, and cannot be adjusted.
-
-
Example: Where an average (i.e. medium) welding amperage of 70 A has been selec-
ted, the gas post-flow time will be 7.5 seconds long.
The diagram below illustrates the chronology of the welding current and the sequence
of the gas-flow when the TIG Comfort Stop function is active:
(1) Welding
(2) Raise torch
TIG Comfort-Stop
Downslope where minimum welding amperage has been selected
(10 A): 1 second
Downslope where max. welding amperage has been selected
(150A): 2 seconds
Gas post-flow time where minimum welding amperage has been selected (10 A):
3 seconds
Gas post-flow time where maximum welding amperage has been selected (150A):
12 seconds
(3) Lower torch
1 4
(4) Keep height constant
(5) Lift off torch