[1-1]
Battery pack
[1-2]
Charger
[1-3]
LED-Display
The battery pack is delivered partially charged.
Charge the battery pack completely before us-
ing for the first time.
To charge the battery pack, put it on the retainer
[1-2] on the charger.
To remove, pull off the charged battery pack.
The LED [1-3] on the charger indicates the respec-
tive operating status of the charger.
There are two elongated holes on the back of the
MXC for mounting the charger to a wall using two
screws (e.g. round head or flat head screw with
shank diameter of 5 mm).
Insert the two screws into the wall at a distance
of 85 mm from one another and leave the screw
heads protruding approx. 3 mm.
4
Functional description
1-1
Charging the battery pack
LED yellow - lit continuously
Charger is ready to use.
LED green - flashing quickly
Battery pack will be charged with max. current.
LED green - flashing slowly
Battery Pack is charged to 80 % and will be charged
with further reduced current.
LED green - lit continuously
Battery pack is fully charged.
LED red - lit continuously
Battery temperature is outside the permitted
range.
LED red - flashing
General fault display, e. g. incomplete contact,
short circuit, battery pack faulty, etc.
Charger wall mounting MXC
3 mm
85 mm
(3
'')
11 32
1-2
1-3