5. Curing/Polymerization Time
Pressure pot:
2.2 bar, 30 lbs p.s i.
Water temperature: 40 – 46 °C / 104 – 115 °F
Time:
20 minutes (no less)
Polymerisation in a pressure vessel
should not be interrupted during the
first 12 minutes if possible to prevent
the formation of microporosity.
6. Shelf Life
Powder/Polymer:
10 years when container is closed.
Liquid/Monomer:
24 months following date of manufac-
ture in the sealed bottle.
• Store in a cool place at not more
than 25 °C / 77 °F.
• Protect from contamination, sunlight
or high temperatures as they may
cause premature polymerization.
7. Hints
Hints for reducing the remaining monomer content
To reduce the remaining monomer content the completed
appliance should be immersed int water for three days, if
possible, before the patient uses it. The watering has the
effect that the remaining monomer is reduced to values
similar to those of heat-curing synthetic resins. Should this
not be possible, it is recommended that the patient also pla-
ces the appliance into water, during the tim it is not worn.
10
orthocryl
®
en
Excerpt from article "Beitrag zur biologischen Beurteilung
kieferorthopädische Kunststoffe" in "Fortschritte der Kiefer-
orthopädie 2000, 61 246-257 (No. 4)."
Hints for the hygiene
Appliances should be cleaned regularly and stored in water
when not in use to prevent problems with hygiene. This pro-
cedure prevents crack corrosion or brown discoloration of
the wire components.
Note
Strict quality controls guarantee a uniform quality for all our
products.
Orthocryl
®
Orthodontic Acrylics have been scientifically
tested. We have information available on request regarding
testing, detailed processing instructions with practical tips,
and the entire Orthocryl
product range.
®
orthocryl
®
en
11