18 en | Installation Manual
Top-view of monitoring zone
Side-view of monitoring zone
6. Fit the top of the housing onto
the housing base and close the
detector. Once the housing is
closed, the LED flashes until a
1.5-second idle period (without
recognized movement) has been
completed.
1
F.01U.045.268 | V4 | 2014.12
CRS-SWM-TA869 | CRS-WM-TA869 | ISA-WM-869
Initial Operation
Configuration
The detector has its own individual
code, which must be communicated
to the Carephone. The detector can
be registered by opening the tamper
contact (opening the housing).
Walk test mode
Once the batteries have been
inserted and the tamper contact has
been closed, the detector will be in
walk test mode for 90 seconds.
Each time a movement is detected,
the time will be reset. During the
last 10 seconds, the LED flashes to
indicate that the walk test function
is about to end. During this time,
there should be no movement.
While in walk test mode, no alarms
will be forwarded to the Carephone.
When movement is detected, the
LED lights up for 4 seconds.
2
Installation Manual
Bosch Security Systems