Horizontal Multi-Stage Pumps; Translation Of The Original Instructions - Franklin Electric EH 3 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

ENGLISH

Translation of the original instructions

1 INTRODUCTION AND SAFETY
This manual contains basic instructions to be observed during installation, use and
maintenance.
It is essential that this manual be consulted by the installation personnel and by
all qualified personnel chosen by the installation manager to follow its operation.
Furthermore, this manual should always be at hand at the site where the pump is
being used.
1.1 Identification of the codified instructions in this manual
WARNING: General danger: inobservance of these safety instructions may
cause physical injury.
WARNING: Electrical hazard: failure to comply with these instructions may
cause an electric shock and resulting serious physical injury or death.
WARNING: Hot surface: inobservance of these safety instructions may
cause physical injury.
Risks deriving from failure to comply with safety regulations
Failure to comply with safety regulations may cause physical injury or material
damage, as well as possible environmental contamination. Inobservance of safety
regulations may lead to the complete loss of warranty rights.
For example, non-compliance with the said regulations may cause:
breakdown of the main functions of the machine or of the installation,
compromised maintenance operations,
electrical, mechanical physical damage.
1.1 General information
This pump has been made according to the most recent, advanced techniques, in
full compliance with current standards and has been subject to strict quality control.
This manual will help you understand its function and learn its possible applications.
The user manual contains important recommendations necessary for correct and
efficient operation.
These recommendations must be observed in order to guarantee reliability and
lifespan and to prevent accidents arising from improper use.
The pump should not be used outside the limits described in the technical
specifications. It is necessary to observe the instructions regarding the nature,
density, temperature and volume of the pumped liquid, rotation speed and direction,
pressure and motor power, as well as all the other instructions contained in this
manual or the documentation attached to the contract.
The data plate indicates the model, the main service specifications and the serial
number. It is important to provide these indications when requesting repairs or
support and when ordering spare parts.
The manufacturer declines all liability for any damage caused, directly or
indirectly, by persons or objects, as a consequence of failure to comply with
all instructions given in this instruction manual and regarding, in particular,
warnings concerning installation, use and maintenance of the electric pump or
in conditions other than those specified on the data plate.
The warranty will be permanently withdrawn in the case of wrong or improper
use of the product, or negligence.
WARNING: This equipment must not be used by children or persons with
reduced physical, sensory or mental abilities, or lacking in experience and
expertise, unless supervised or trained.
WARNING: Children may not use the equipment and must not play with the
pump or in the near vicinity.
WARNING: For all normal operations of installation/commissioning and
functioning of the machine it is not necessary to remove the protective
devices (motor fan cover).
EC declaration of conformity
In accordance with Annexe II.A of Directive 2006/42/EC
Franklin Electric s.r.l., Via Asolo, 7 - 36031 - Dueville - Vicenza - Italia
declares that the machine:
PUMP MODEL: EH
SERIAL NUMBER: (SEE STICKER ON LAST PAGE AND PUMP DATA PLATE)
is compliant with the following Directives:
• Machinery Directive 2006/42/EC
• Low Voltage Directive 2006/95/EC
• Electromagnetic Compatibility Directive 2004/108/EC
Ecodesign Directive 2009/125/E, RULING (EC) 640/2009
(MOTOR 3~, 50Hz, PN≥ 0.75 kW 50Hz) if marked IE2 or IE3
and with the following technical standards:
• EN 809:2009
• EN 60335-1:2013, EN 60335-2-41:2005
• EN 62233:2005
• EN 61000-6-1:2007, EN 61000-6-3:2007
• EN 60034-30-1:2014
The person authorised to compile the technical file is:
Franklin Electric s.r.l., Via Asolo, 7 - 36031 Dueville – VI - Dueville, 01/03/2015
Riccardo Fornasa
Director of Engineering - R&D
2 PRELIMINARY INSPECTION
2.1 Delivery and packing
The pumps are supplied in their original packing, in which they should remain until
the time of installation.
8
EN

HORIZONTAL MULTI-STAGE PUMPS

Check externally that the packing is free from damage. If the product appears to
be damaged, inform the reseller immediately. The pump should not be exposed to
unnecessary shocks and impacts.
2.2 Contents of packing
The packing contains the operating and installation manual and the electric pump.
3 STORAGE AND HANDLING
3.1 Storage:
Storage temperature: from -5°C to +40°C.
The electric pump must be kept indoors in a dry place, away from heat and protected
from dirt and vibrations.
3.2 Handling:
WARNING: Observe the accident prevention regulations in force. Risk of
crushing. The pump may be heavy. Use suitable lifting methods and always
wear personal protection equipment.
Before handling the product, check its weight to identify suitable lifting equipment.
The weight is indicated on the pump data plate.
There are two possible methods for handling the pump:
1) Where indicated, remove the cap and screw on a lifting eyebolt suitable for the
weight involved. Warning: The eyebolt does not correspond to the centre of
gravity (see fig. 1-C).
2) Position the hoist cables as shown in (fig. 1-A) and (fig. 1-B).
Take the pump out of its packing and check that it is in good condition.
Check also that the plate data correspond to those required. In the event of any
anomaly, contact the supplier immediately, reporting the nature of the defects.
4 GENERAL INFORMATION
4.1 General description
This product is a non self-priming, close-coupled, multi-stage, horizontal pump,
with an electric motor.
The pump can pump hot or cold water. The metal parts in contact with liquid are
made of stainless steel.
Pump identifi cation code
/
EH 15
03
I
015
T
5 E1
Permitted use
The pump is suitable for:
• Civil and industrial water distributions systems,
• Irrigation,
• Water treatment,
• Washing systems,
• HVAC (heating and cooling)
Non-permitted use
The pump is not suitable for:
• Pumping liquids not compatible with construction materials.
• Pumping dangerous liquids (e.g. toxic, explosive, infl ammable or corrosive
liquids),
• Pumping liquids for human consumption other than water (for example wine or
milk),
• Pumping liquids containing abrasive, solid or fi brous substances,
• Working outside of the rated capacity range specifi ed on the data plate.
Examples of improper installation:
• Environments with explosive or corrosive atmospheres,
• Outdoor installations without protection from the weather (e.g., sun, rain, high or
freezing temperatures).
WARNING: Do not use this pump for inflammable or explosive liquids.
Misuse may create hazardous conditions and cause personal injuries and
material damage. Misuse of the product renders the warranty void.
Special use:
Contact the sales and service office:
• If the pump is used to pump liquids with viscosity or density greater than water (a
motor with proportionately higher power should be used),
• If the water to be pumped has been chemically treated (softened, chlorinated,
demineralised etc.),
• In any other situation other than those listed for permitted use.
4.2 Technical data
4.2.1 Temperature of the liquid
Pumped liquids must remain within certain temperature limits:
with EPDM seals (standard versions): from -15°C to +110°C,
IE2
Motor efficiency class
Blank (Standard version); A (Cable with plug);
S (Condensate drain without caps)
Blank (Standard version); P (Passivated)
Blank (Standard version); D (Seal housing disc with plug)
Type of mechanical seal
Frequency: 5 (50Hz); 6 (60Hz)
M (single phase); T (three phase)
Motor power (kW x 10)
Pump material: I (AISI304); N (AISI316)
Number of stages
Nominal capacity in m³/h
Pump model

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Eh 5Eh 9Eh 15Eh 20

Table des Matières