Installation, Transferring Works, And Checking; Specifi Cations - Mitsubishi Electric City Multi PEFY-P06NMAU-E2 Manuel D'utilisation

Masquer les pouces Voir aussi pour City Multi PEFY-P06NMAU-E2:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

7. Installation, transferring works, and checking

Regarding place for installation
Consult with your dealer for details on installation and transferring the installation.
Caution:
Never install the air conditioner where there is a risk of leakage of fl am-
mable gas.
If gas leaks and accumulates around the unit, fi re can result.
Never install the air conditioner at the following place:
where there is a lot of machine oil
near the ocean and beach areas where there is salt air.
where humidity is high
where there are hot springs nearby
where there is sulphurous gas
where there is a high-frequency processing machinery (a high-frequency welder,
etc.)
where acid solution is frequently used
where special sprays are frequently used
Install the indoor unit horizontally. Otherwise, water leakage can result.
Take suffi cient measures against noise when installing the air conditioners at
hospitals or communication-related businesses.
If the air conditioner is used in any of the above-mentioned environments, frequent
operational failure can be expected. It is advisable to avoid these types of instal-
lation sites.
For further details, consult with your dealer.
Regarding electrical work
Caution:
The electrical work must be undertaken by a person who is qualifi ed as an
electrical engineer according to the [technical standard respecting elec-
trical installation], [internal wiring rules], and the installation instruction
manual with the absolute use of exclusive circuits. The use of other prod-
ucts with the power source can result in burnt-out beakers and fuses.
8. Specifi cations
PEFY-P-NMAU-E2 series
Item
Power source
1
Cooling capacity*
/ Heating capacity*
Height
Dimension
Width
Depth
Net weight
Airfl ow rate(Low-Mid-High)
Fan
External staticpressure*
2
3
Sound level(Low-Mid-High)*
*
Filter
Item
Power source
Cooling capacity*
1
/ Heating capacity*
Height
Dimension
Width
Depth
Net weight
Airfl ow rate(Low-Mid-High)
Fan
External staticpressure*
Sound level(Low-Mid-High)*
2
*
3
Filter
Model
P06NMAU-E2
Btu/h
6,000/6,700
1
kW
1.8/2.0
mm[in]
mm[in]
mm[in]
kg[lb]
CFM
212-265-300
in.WG
2
[Pa]
dB(A)
26-28-29
Model
P24NMAU-E2
Btu/h
24,000/27,000
1
kW
7.0/7.9
mm[in]
mm[in]
mm[in]
kg[lb]
CFM
618-742-883
in.WG
2
[Pa]
dB(A)
30-34-39
Never connect the grounding wire to a gas pipe, water pipe, arrester, or
telephone grounding wire. For details, consult with your dealer.
In some types of installation sites, the installation of an earth leakage
breaker is mandatory. For details, consult with your dealer.
Regarding transfer of installation
When removing and reinstalling the air conditioner when you enlarge your
home, remodel, or move, consult with your dealer in advance to ascertain the
cost of the professional engineering work required for transferring the instal-
lation.
Caution:
When moving or reinstalling the air conditioner, consult with your dealer.
Defective installation can result in electric shock, fi re, etc.
Regarding noise
In installing work, choose a place that can fully bear the weight of the air con-
ditioner, and where noise and vibration can be reduced.
Choose a place where cool or warm air and noise from the outdoor air outlet
of the air conditioner does not inconvenience the neighbors.
If any alien object is placed near the outdoor air outlet of the air conditioner,
decreased performance and increased noise can result. Avoid placing any
obstacles adjacent to the air outlet.
If the air conditioner produces any abnormal sound, consult with your dealer.
Maintenance and inspection
If the air conditioner is used throughout several seasons, the insides can get
dirty, reducing the performance.
Depending upon the conditions of usage, foul odors can be generated and
drainage can deteriorate due to dust and dirt, etc.
P08NMAU-E2
P12NMAU-E2
208, 230V 60Hz
8,000/9,000
12,000/13,500
2.3/2.6
3.5/4.0
250[9-13/16]
700[27-9/16]
732[28-7/8]
22[49]
212-265-300
265-318-371
0.14-0.20-0.28-0.40-0.60
[35/50/70/100/150]
26-28-29
28-30-34
Standard fi lter
P27NMAU-E2
P30NMAU-E2
208, 230V 60Hz
27,000/30,000
30,000/34,000
7.9/8.8
8.8/10.0
250[9-13/16]
1,100[43-5/16]
732[28-7/8]
30[67]
618-742-883
618-742-883
0.14-0.20-0.28-0.40-0.60
[35/50/70/100/150]
30-34-39
30-34-39
Standard fi lter
P15NMAU-E2
P18NMAU-E2
15,000/17,000
18,000/20,000
4.4/5.0
5.3/5.9
900[35-7/16]
26[58]
353-424-494
424-512-600
28-30-34
28-32-35
9

Publicité

Chapitres

Table des Matières
loading

Table des Matières