5.4 Pneumatic safety
16
•
Depressurize the system!
–
Switch off the compressed air supply before working on the circuit.
–
Check the system with pressure gauges to make sure that the entire circuit is
pressure-free.
–
Please note that energy may be stored in pressure reservoirs.
Further information on this issue is available in the datasheets and operating
instructions included with the components.
•
Risk of injury when switching compressed air on!
Cylinders may advance and retract automatically.
•
Risk of accident due to advancing cylinders!
–
Always position pneumatic cylinders so that the piston rod's working space is
unobstructed over the entire stroke range.
–
Make sure that the piston rod cannot collide with any of the rigid components in
the setup.
•
Risk of accident due to pneumatic tubing slipping off!
–
Use shortest possible tubing connections.
–
If pneumatic tubing slips off:
Switch off the compressed air supply immediately.
•
Do not exceed the maximum permissible pressure of 6 bar (600 kPa).
•
Do not switch on the compressed air until all the tubing connections have been
established and secured.
•
Do not disconnect pneumatic tubing while under pressure.
–
Do not attempt to connect pneumatic tubing or push-in connectors with your
hands or fingers.
WARNING