Parker Hiross StarlettePlus SPS026-ES Manuel D'utilisation page 11

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 21
5
Control
QS
Main power switch
UP button: press to increase the value of a selected parameter
DOWN button: press to reduce the value of a selected param-
eter, press for more seconds to force the drain to work.
esc
ESC button :returns to the previous level
SET button : one single press to see the alarms, press for more
set
seconds to ON/OFF the dryer
(illuminated) Dew point correct
(Flashing) warning dew point high/low
(off) alarm dew point
(illuminated) Condensate drain ON
(off) Condensate drain OFF
(illuminated) Dryer ON
(off) Dryer OFF / Dryer stand by
(illuminated) with compressor OFF
(illuminated) Allarm
(Led illuminated
) Maintenance
°C
(Led illuminated
) Grade
°F
Bar
(Led illuminated
) Pressure
PSI
English
5.1 Parameter settings
There are two levels of protection for parameters:
a) User (U): with immediate access, User-changeable;
b) Password protected Factory/Service (F/S): password required for ac-
cess; Factory/Service use only.
5.2 Condensate drain
Ii is possible to modify the operating modes of the drain, using the
"TIME" menu.
There are two operating modes:
a) TIMED (CHd = ON) - with draining at intervals and settable time;
in this confi guration keep pressed
to force the drain to work;
b) EXTERN (CHd = OFF) - if there is an external drain.
Parameter table "TIME"
Code
Defi nition
dON
Time ON Drain (sec.)
dOFF
Time OFF Drain (1=10 sec.)
CHd
Confi guration drain
For choosing the set proceed as follows (or see the fl ow chart):
esc
set
Press buttons
and
together over 5 seconds to enter on sub-
menu.
Using buttons
and
select "Par" and press
Using buttons
and
select "TIME" and press
Using buttons
and
select the code to change and press
to confi rm.
Using buttons
and
change the value and press
esc
Press
to exit.
In the same way it is possible to change interval and discharge times of
the drain.
5.3 Software menu
It is possible to see the software version and set the dryer for the remote
control or the supervisor in the menu "CF9".
Parameter table "CF9"
Code
Defi nition
VER
Software Version
SOFt
Software type
rE
On/Off remote
(Table 1)
SUP
ON/OFF supervisor (Modbus)
SPS026 / SPS100-ES
Table 1
0
On/Off remoto disable
1
On/Off remote enable, local On/Off enable
2
On/Off remote enable, local On/Off disable
For choosing the set proceed as follows (or see the fl ow chart):
set
Press buttons
Using buttons
Using buttons
Using buttons
to confi rm.
Using buttons
Default Min
Max.
esc
Press
to exit.
5
1
60
12
2
270
Machine status
To get the machine status signal you have to connect to the following
OFF
ON
OFF
powered contacts (0-10V):
1) A1 on J3 on clamp A04
2) X1 on clamp GND
State ON (contact closed =10V)
set
State OFF (contact open = 0V)
to confi rm.
set
Machine
to confi rm.
status
set
ON
OFF
set
to confi rm.
OFF
OFF
* in case of no power supply or loss.
Default Min
Max.
1.0
---
---
1
---
---
0
0
2
OFF
OFF
ON
On/Off remote mode
esc
and
together to enter on submenu.
set
and
select "Par" and press
to confi rm.
set
and
select "CF9" and press
to confi rm.
and
select the code to change and press
set
and
change the value and press
ON/OFF
energy
power supply
display
saving
of alarms
YES
ON
NO*
ON
not
infl uent
YES
OFF
NO*
OFF
3 / 6
set
to confi rm.
presence
not
infl uent

Publicité

Table des Matières
loading

Table des Matières