I N S TA L L AT I O N
I N S T R U C T I O N S
F R A M E D
M O D E L I C B C T 3 0 I / S
The illustrations below provide installation
specifications for Model ICBCT30I/S.
For ease of installation, 838 mm cabinets are
recommended for installation of Model
ICBCT30I/S.
Wolf 762 mm or 914 mm built-in single oven
may be installed below Model ICBCT30I/S. For
this installation, unless you are using cabinets
deeper than 610 mm, it is recommended that
the electrical supply be placed in the base
cabinet to the right of the oven.
I N S TA L L AT I O N S P E C I F I C AT I O N S – M O D E L I C B C T 3 0 I / S
762 mm
OVERALL WIDTH
64 mm
TERMINAL BOX
Overall Dimensions
M O D E L I C B C T 3 0 I / S
Overall Width
Overall Height
Overall Depth
Minimum Cabinet Depth
Minimum Height Clearance*
Cut-Out Width
Cut-Out Depth
*Minimum 152 mm clearance is required
between countertop and any combustible
surface directly below the cooktop.
For detailed terminal block dimensions,
refer to the illustration on page 7.
Dimensions may vary to ± 3 mm.
Refer to installation instructions provided with
the built-in oven for additional specifications.
If Model ICBCT30I/S is installed above
cabinets, the electrical placement is not critical.
The appliance shall be installed in such a way
to allow disconnection of the appliance from
the supply mains after installation.
533 mm
OVERALL
DEPTH
SIDE
CABINET
330 mm
max
96 mm
51
mm*
762 mm
64 mm
533 mm
*Minimum clearance from cooktop cut-out to combustible materials up to 457 mm above countertop.
578 mm
NOTE: Electrical location applies only to installation with built-in oven.
96 mm
721 mm
489 mm
762 mm
COUNTERTOP
TO COMBUSTIBLE
MATERIALS
51 mm
TO
*
COMBUSTIBLE
914 mm
FLOOR TO
COUNTERTOP
min
457 mm
min
51 mm
SEE COUNTERTOP
CUT-OUT BELOW
COMBUSTIBLE
114 mm
89 mm
E
254 mm
762 mm OVEN OPENING
721 mm
CUT-OUT WIDTH
489 mm
CUT-OUT
DEPTH
64 mm
FRONT
min
COUNTERTOP CUT-OUT
TO
*