Télécharger Imprimer la page

Overall Dimensions - Wolf ICBCT15I /S Instructions D'installation

Publicité

Les langues disponibles
  • FR

Les langues disponibles

W O L F
U N F R A M E D
The illustrations below provide installation
specifications for Model ICBCT30IU.
For ease of installation, 838 mm cabinets are
recommended for installation of Model ICBCT30IU.
installed below Model ICBCT30IU. For this
installation, unless you are using cabinets
deeper than 610 mm, it is recommended that
the electrical supply be placed in the base
cabinet to the right of the oven. Refer to instal-
lation instructions provided with the built-in
oven for additional specifications.
I N S TA L L AT I O N S P E C I F I C AT I O N S – M O D E L I C B C T 3 0 I U
762 mm
OVERALL WIDTH
76 mm
TERMINAL BOX

Overall Dimensions

M O D E L I C B C T 3 0 I U
Overall Width
Overall Height
Overall Depth
Minimum Cabinet Depth
Minimum Height Clearance*
Cut-Out Width
Cut-Out Depth
*Minimum 165 mm clearance is required
between countertop and any combustible
surface directly below the cooktop.
For detailed terminal block dimensions,
refer to the illustration on page 7.
Dimensions may vary to ± 3 mm.
12
I N D U C T I O N C O O K TO P S
M O D E L I C B C T 3 0 I U
Wolf 762 mm built-in single oven may be
533 mm
OVERALL
DEPTH
CABINET
330 mm
98 mm
51
mm*
762 mm
76 mm
533 mm
*Minimum clearance from cooktop cut-out to combustible materials up to 457 mm above countertop.
578 mm
NOTE: Electrical location applies only to installation with built-in oven.
98 mm
721 mm
492 mm
22
mm
max
RECESS FOR FLUSH INSTALLATION
SIDE
max
914 mm
FLOOR TO
COUNTERTOP
COUNTERTOP
PROFILE
8 mm
If Model ICBCT30IU is installed above cabinets,
electrical placement is not critical. The appli-
ance shall be installed in such a way to allow
disconnection of the appliance from the supply
mains after installation.
For Model ICBCT30IU installation options, refer
to Unframed Installations on pages 14–15.
IMPORT NT NOTE: For flush mount applica-
tions, it is recommended to measure the
cooktop glass before cutting the countertop to
ensure a proper fit. Small variances may exist
between the template and the cooktop.
762 mm
min
COUNTERTOP
TO COMBUSTIBLE
MATERIALS
51 mm
TO
SEE COUNTERTOP
*
COMBUSTIBLE
CUT-OUT BELOW
89 mm
762 mm OVEN OPENING
765 mm
RECESS FOR FLUSH INSTALLATION
33 mm
721 mm
RADIUS
CUT-OUT WIDTH
11 mm
RADIUS
537 mm
RECESS
FOR FLUSH
INSTALLATION
FRONT
40 mm
COUNTERTOP CUT-OUT
457 mm
min
51 mm
TO
*
COMBUSTIBLE
114 mm
E
254 mm
492 mm
CUT-OUT
DEPTH
62 mm
min

Publicité

loading

Ce manuel est également adapté pour:

Icbct30i /sIcbct36i /s