I M P O R TA N T
3 8 1 m m I N D U C T I O N C O O K T O P S
N O T E
Required power supply:
Be aware of local
codes and ordi-
Maximum connected load:
nances when
installing your
service.
Total amps:
7 6 2 m m I N D U C T I O N C O O K T O P S
Required power supply:
Maximum connected load:
Total amps:
16
I N D U C T I O N C O O K TO P S
R E Q U I R E M E N T S
Verify that power is disconnected from
the electrical box before proceeding.
Single phase: 220-240V C; 50 Hz
3phase: 380-410V C; 50 Hz
Single phase: 3.6 kW
3phase: 3.6 kW
Single phase: 16 amps
3phase: 16 amps
Single phase: 220-240V C; 50 Hz
3phase: 380-410V C; 50 Hz
Single phase: 7.2 kW
3phase: 3.6 kW
Single phase: 32 amps
3phase: 16 amps
˜
L1
N
Single phase wiring diagram
9 1 4 m m I N D U C T I O N C O O K T O P S
Required power supply:
Single phase: 220-240V C; 50 Hz
3phase: 380-410V C; 50 Hz
Maximum connected load:
Single phase: 11.2 kW
3phase: 4 kW
Total amps:
Single phase: 49 amps
3phase: 18 amps
Refer to the wiring diagram showing the
connections for each lead to the terminal box
on the unit.
3N
˜
L1
L2
L3
N
3phase wiring diagram