Anleitung NSG 180 F_SPK1
GB
Important!
Always use tongs to remove spent electrodes and to
move parts that you have just welded. Please note
that the electrode holder (1) must always be put
down so that it is insulated after you have completed
the welding work.
Do not remove the slag until the weld has cooled.
If you want to continue a weld after an interruption,
the slag from your initial attempt must first be
removed.
9. Overheating guard
The welding set is fitted with an overheating guard
that protects the welding transformer from
overheating. If the overheating guard trips, the
control lamp (5) on your set will be lit. Allow the
welding set to cool for a time.
10. Socket (14)
The welder has a 230 V/50 Hz socket on the back
side protected by a 6 A overload switch (13). The
overload switch (13) actuates if the socket (14) is
overloaded. Following the cool down phase, the
socket (14) can be reactivated using the overload
switch (13). The socket is designed for electric tools
with a maximum power consumption of 600 W.
Important!
Do not use tools during welding work.
11. Maintenance
Remove dust and dirt from the machine at regular
intervals. Cleaning is best carried out with a fine
brush or a cloth.
12. Ordering replacement parts
Please quote the following data when ordering
replacement parts:
Type of machine
Article number of the machine
Identification number of the machine
Replacement part number of the part required
For our latest prices and information please go to
www.isc-gmbh.info
14
03.05.2006
12:08 Uhr
Seite 14