2 TRANSPORT AND INSTALLATION
2.1 Packing, handling, shipment and transport
The stove complete with packing can be lifted using a lift truck, inserting the forks (of suitable length) in the special
spaces in the wooden pallet. Make sure the equipment used for lifting and transport can take the weight of the stove,
specified on the dataplate and in this manual.
Avoid taking the load in areas where it could be a danger if dropped.
Open the packing, remove the stove from the pallet and position it in the required place, making sure it complies with
that provided for.
Set the stove down on the floor carefully without bumping and position it in the required place. Make sure the floor
can take the weight of the stove, otherwise consult a specialised technician.
Disposal or recycling of the packing must be carried out by the end-user in compliance with the current local
regulations.
2.2 Place of installation, positioning and fire-prevention safety
The place of installation must be sufficiently ventilated to allow the removal of any combustion smoke leaks.
The unit is suitable for operation in domestic environments with min. temperature of 0° C; it comes com plete with an
antifreeze function that activates the heating pump for system water temperatures below 6° C, safeguard ing: the
heating chamber, heating/DHW circuit. The antifreeze function is active only when the stove is electrically powered.
To prevent the risk of fire, the structures surrounding the stove must be protected from the heat. For example, floors
in wood or flammable material must be suitably protected with steel panels or toughened glass. Any wooden boards
or beams above or crossed by the flue must be suitably protected in conformity with the requirements of the specific
current installation standards. Suitable fire-prevention devices should be arranged for any eventuality.
The minimum front distance for the protection of flammable objects is 1.5 m. The minimum safety distances from
flammable materials must be at least 0.2 m and in any case comply with the following table:
Every installation must provide for an easily accessible technical space for periodical maintenance.
The stove is provided with 4 adjustable feet to facilitate positioning on not perfectly flat floors. To adjust the height,
tilt the stove slightly and turn the feet as required.
The stove is supplied with the ambient sensor fixed through a wrapper on the back of the stove; we recommend to
remove the wrapper and to locate the sensor in the best position possible as to improve the temperature registration
in accordance with the ambient context and the length of the cable.
As for temperature registration done at a certain distance we reccomend to install the ambient thermostat/ambient
programming clock-thermostat – see. par.4.8.
-The stove cannot be installed in bedrooms, bathrooms and in general in rooms where another heating
unit , is already installed without an independent air inflow.
- With wooden floors, install a floor protection base in conformity with the current regulations.
- Suitable fire prevention devices should be arranged for any eventuality.
- Do not install the stove in places with an explosive atmosphere.
A = 200 mm
B = 200 mm
Wall air inlet
min. 100 cm²
Floor protection base
43
1500
TERMO-BLITZ