21. Replacing a filter
Water volume regulator filter
21.1 Remove the shower panel (see
21.2 Unscrew the locking screws (a) on the water volume regulators.
21.3 Replace the filters (b).
☞
Important!
Note the installation position of the filters.
21.4 Reassemble in reverse order.
22. Flow quantity regulator Exchanging the flow quantity regulator
22.1 Use a face spanner to loosen the retaining ring and remove it.
22.2 Remove the following parts from the shower head.
a: Ball
b: Seal
22.3 Replace the flow rate regulator (c).
23. Troubleshooting
Fault
Water does not flow
Water flows
continuously
Flow time too short or
too long
Water volume too low
If you cannot rectify a fault or if it is not in the list, please contact our customer
service department!
12
chapter
Cause
– Water supply interrupted
– Water volume regulator closed
– Power supply interrupted
– Dirty filters
– Solenoid valve faulty
– Sensor faulty
– Solenoid valve faulty
– Incorrect flow time setting
– Water volume regulator not fully open
– Shower head calcified
– Dirty filter
– Supply pressure too low
19.).
Remedy
➯ Restore it
➯ Open it
➯ Restore it
➯ Replace it
➯ Replace it
➯ Replace it
➯ Replace it
➯ Set it
➯ Open it
➯ Clean it
➯ Clean it
➯ Check it