17. Maintenance and care

The fitting must be checked and maintained at regular intervals depending on the
water quality and in accordance with the local conditions, and rules and regulations
applicable at the site.
Maintain the following components:
• Shower head (see instructions for shower head)
• Filters (see
Use suitable cleaning agents which are not harmful to the fitting in a proper manner
and rinse with water after use. High-pressure cleaners must not be used for
cleaning.
Remove the cover plate
For some maintenance tasks, the cover plate must be removed.
17.1 Remove the screws from the bottom of the cover plate (a).
17.2 Pull the bottom of the cover plate (b) forwards and detach at the top.
17.3 Close the water volume regulator (see
17.4 Disconnect the fitting.

18. Replacing the filters

Water volume regulator filters
18.1 Remove the cover plate (see
18.2 Unscrew the locking screws (a) on the water volume regulators.
18.3 Replace the filters (b).

Important!

Note the installation position of the filters.
18.4 Reassemble in reverse order.