Taipei
Insert
X-20F
Steel chimney
Can be connected to steel chimney.
Weight including insert
CC-TAI01-000 - Taipei Colorado natural
CC-TAI03-000 - Taipei Colorado white
accessories
MZ-TAI00-03D - Rusty brown front
MO-TAI00-020A - Bianco carrara front
Floorplate
Please follow the rules and regulations regarding
floorplates in your country.
Safety Distances (FIG 2)
Ensure that the safetdistances are complied with.
Please note that these safety distances can vary from
country to country.
Illustration (FIG 1 / 1a Taipei=mm)
*The illustration indicates the approximate centre height
of the hole for the flue. Consider possible inclination of
the flue prior to perforating the chimney. Distortions in
floors and walls may influence the height. Dry stack
the fireplace for accurate height and positioning of
the flue/chimney connection. If a fresh air supply set
(accessory) is connected through the floor, prepare the
bottom element before assembly.
Fresh air supply (accessory)
ATTENTION! The product can only be connected to
the fresh air supply through the pre cut areas in the
surround (See FIG 1a Taipei =AIR). Seal off the gap
between the fresh air hose and the concrete with a
non combustible sealant.
For more information see separate assembly
instructions for fresh air supply.
Assembly instructions FIG 3-30
196 kg
196 kg
3 kg
20 kg
GB
7