MODE key (blue) J :
MIN/MAX key 9 :
HOLD/ZERO key 5 :
HFR 8
5.1.14 Temperature coefficient of the measured value: 0.2 x (stated measuring
accuracy)/ °C < 18 °C or > 28 °C, related to the value for the reference
temperature of 23 °C.
5.1.15 The BENNING CM 10-PV is supplied by means of two 1.5 V batteries
(IEC LR6/ AA).
5.1.16 The battery indication M continuously shows the remaining battery ca-
pacity via a maximum of three segments. When switched on, the device
additionally displays the battery status "Full" (full), "HALF" (half) or "Lo"
(low).
As soon as all segments of the battery symbol have disappeared
and the battery symbol is flashing, the batteries must be re-
placed by new ones immediately in order to prevent danger for
persons caused by incorrect measurements.
5.1.17 The battery life is approximately 200 hours without using the display
illumination and the Bluetooth
5.1.18 Dimensions of the BENNING CM 10-PV: (L x W x H) = 240 x 86 x 48 mm
Weight: 445 g with batteries
5.1.19 Current clamp opening: 37 mm
5.1.20 The safety measuring leads supplied are expressly suited for the rated
voltage and the rated current of the BENNING CM 10-PV.
5.1.21 The BENNING CM 10-PV supports wireless data transmission via the
Bluetooth
let).

5.2 Data logger functions

The data logger (LOG) allows the automatic and manual storage of series of
measurements with a predefined measuring interval (sampling rate) and up to
4000 measured values. The measuring interval can be set from 1 s to 60 s. The
measured values can be read out later via Bluetooth

5.2.1 Setting the data logger

To set the data logger, press the Bluetooth
on the BENNING CM 10-PV via the rotary switch 6 . The current setting is shown
by a symbol on the digital display K . As soon as the symbol appears, press the
Bluetooth
key 7 repeatedly to select from the following functions:
®
Symbol:
„LOG"
„SAVE"
„CLR"
A selected function will be automatically accepted after 2 seconds and remains
permanently stored.
03/ 2020
4.0 standard to an Android or IOS device (smartphone/tab-
®
Function:
Automatic storage with predefined measuring interval
Manual storage by pressing a key
Deleting the internal measured value memory
BENNING CM 10–PV
Setting the APO time to 5/10/20 min. or switching off
the APO function, "OFF" is shown on the display.
Each time the key is pressed again, the value changes.
Unit of temperature in °C or °F
Displaying all display symbols
Displaying the firmware version
function (alkaline battery).
®
key 7 and simultaneously switch
®
for further processing.
®