Technical Data Of Measuring Accessories ( Benning Cm 1-2); Environmental Note - Benning CM 1-1 Notice D'emploi

Masquer les pouces Voir aussi pour CM 1-1:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 21
-
Connect the new battery/batteries to the battery supply lines and arrange
them in such a way that they are not crushed between the housing parts
(BENNING CM 1-1). Then, place the batteries into the battery compartment
at the provided place.
-
Lock the battery compartment cover into place on the bottom part and tight-
en the screws.
See figure 6a, 6b:
Make your contribution for environmental protection! Do not
dispose of discharged batteries via the household waste.
Instead, return them to a collecting point for discharged
batteries or spezial waste. Please look for information in your
community's facilities.
9.4 Calibration
Benning guarantees compliance with the technical and accuracy specifications
stated in the operating manual for the first 12 months after the delivery date.
To maintain accuracy of the measuring results, the device must be recalibrated
in regular intervals by our factory service. We recommend recalibrating the de-
vice once a year. For this purpose, send the device to the following address:
Benning Elektrotechnik & Elektronik GmbH & Co. KG
Service Center
Robert-Bosch-Str. 20
D - 46397 Bocholt
10. Technical data of the measuring accessories ( BENNING CM 1-2)
-
Standard: EN 61010-031,
-
Maximum rated voltage to earth () and measuring category:
With push-on caps: 1000 V CAT III, 600 V CAT IV,
Without push-on caps: 1000 V CAT II,
-
Maximum rated current: 10 A,
-
Protection class II (  ), continuous double or reinforced insulation,
-
Contamination class: 2,
-
Length: 1.4 m, AWG 18,
-
Ambient conditions:
Barometric height for measurements: max. 2000 m,
Temperature: 0 °C to + 50 °C, humidity 50 % to 80 %
-
Use the measuring leads in perfect and clean condition as well as according
to these operating instructions only, as otherwise the protection provided
might be impaired.
-
Replace the measuring leads, if the insulation is damaged or if the conduc-
tor/ connector is interrupted.
-
Do not touch the bare contact tips of the measuring leads. Only touch the
area intended for your hands!
-
Insert the bent terminals into the testing or measuring device.

11. Environmental note

At the end of product life, dispose of the unserviceable device via
appropriate collecting facilities provided in your community.
02/ 2018
Battery replacement
BENNING CM 1-1/ 1-2
14

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Cm 1-2Cm 1-3044061044062044063

Table des Matières