II - Installation
Choose a location where to install the clock, preferably away from sources of electrical interference,
such as transformers. The data network must be PoE (802.3af, class 3).

2.1 Wall installation by screws

Clocks for indoor use are simply mounted by hanging on a screw head (see dimensions page 20).
1) Position a screw (Ø 4) at the required height, leaving the head protruding by 3mm.
2) Connect the clock to the data network. See next page about the connection of this cable.
3) Put the clock in its position.

2.2 Wall installation by secure wall mounting bracket

1) Run the cables through the hole and fit the wall bracket using 4 screws Ø6.
2) Connect the clock to the data network. See next page about the connection of this cable.
3) Present the clock on the wall bracket (1), then turns it a quarter turn in the clockwise so that the
clock is in the correct position.
1
Wall bracket:
Fit the disk on the back of the clock and turn it clockwise in order to lock it on
the clock? The passageway for the cables must be at the bottom of the disk.

2.3 Mounting on support double-sided

1) Fix the double-sided support to the wall or ceiling, using 2 Ø6 screws (see dimensions page 20).
2) Connect the clock which will be the master of the double sided assembly to network
with Ethernet cable RJ45. See next page about the connection of this cable.
This cable provides network communication and power to the clocks (PoE: Power over Ethernet).
3) Connect RJ12 cable on the master clock.
4) Connect to the second clock (slave), the master clock by the RJ12 cable only (photo 2).
Do not use a standard telephone cable RJ11.
Do not connect an Ethernet PoE cable to the RJ45 of the slave clock
5) Present the clocks to the support, then turn them clockwise to their
final positions.
Attention: in.its double sided version this clock may weigh up to 17 kg. Mechanical strains
when locking the clock on the bracket must also be taken into account, this is why we
recommend installing this double sided clock on concrete walls.