From the menu SETTINGS  OPERATIONS it is possible to access the pages to save the configuration directly to files, PC or a USB drive.
Clicking on the related bottons will automatically save an XML file containing the complete D-MATRIX-4S FTA configuration directly on the PC
or a USB drive.
Once one or more configuration files have been saved on the PC or a USB drive, the configuration can be loaded into the D-MATRIX-4S FTA:
clicking on the load configuration buttons (from file, form USB) will load a previously saved configuration file.
Select the saved configuration file and confirm the download by clicking on "Upload configuration".
When clicking on the Factory Default button it is possible to reset the product with the factory default settings.
Clicking on the Reboot button will restart the module.
From the menu SETTINGS  FIRMWARE UPDATE you can check which firmware release is installed and then update the system if required.
To update the system, check there is correct update package available in a PC folder, or in a USB drive, then select it and press on BROWSE and
then UPDATE MODULES. Wait for the operation to finish.
It is possible to configure D-MATRIX-4S FTA in a quick and easy way with the following procedure:
Create a configuration via web
Export to a file from the Settings -> Operations menu. The file name will be All_date_time.xml
Copy the file to a USB memory and name it FR_AUTOCONF_D-MATRIX-4S_FTA.FR (please pay attention to lowercase letters, dashes and
extension)
Insert the USB memory into another D-Matrix-4S FTA that must be switched on
The front LED will flash 3 times in green and orange and then D-Matrix-4S FTA will reboot with the new configuration from the USB memory
The autoconfiguration does not work if the D-Matrix is switched on with the USB memory plugged in. Insert the USB memory while the unit is on.
5.3 OPERATIONS MENU
Fig. 13
5.4 FIRMWARE UPGRADE
Fig. 14
5.5 AUTOCONFIGURATION PROCEDURE