D-MATRIX-4S FTA has four multicolour LEDs on the top (one for each input), to indicate the sat signal reception status, and one multicolour led
on the bottom showing the system status.
The following table gives a useful summary to interpret the lighted LEDs.
INPUT STATUS LED
Off:
Input off
Orange:
Input active waiting to lock
Green:
Input active and locked
Red:
Input overloaded
SYSTEM STATUS LED (during initialisation)
Orange:
Boot system
Red:
start applications
Green:
System started without error
SYSTEM STATUS LED (system started)
Green:
Normal
Orange:
Anomaly
Flashing red: Update and/or recovery phase
Wait until the D-MATRIX-4S FTA is initialized (the display shows D-MATRIX FRACARRO)
To access the panel menu, press V, type in the user code (default code is 1234) and confirm by pressing V.
Program as instructed below (see the paragraph 5.1. BASE PROGRAMMING FROM THE PANEL).
Check the output signal is available by using a field meter
Connect the distribution cable to the output connector
A PC can be used alternatively to configuration from the panel, by accessing the programming using a web interface (see the paragraph 5.2
PROGRAMMING BY WEB INTERFACE).
If required, the product can be reset to the factory.
ATTENTION: in this condition English is the default language.
After resetting the factory settings, the D-MATRIX-4S FTA will have to be reprogrammed, as the preset parameters may not coincide with the
required ones.
After configuring the network parameters using the front panel and connecting to the local network, or to a PC using a cross lead, the web
browser can be used.
EXAMPLE (DIRECT CONFIGURATION FROM A PC):
Change the IP address using one that belongs to the same subnet as the one set in the local net card on the PC.
Parameters set in the PC net card
IP: 192.168.0.3
SUBNET MASK: 255.255.255.0
GATEWAY: 192.168.0.1
Parameters to change in the D-MATRIX-4S FTA network settings:
IP: 192.168.0.2
SUBNET MASK: 255.255.255.0
GATEWAY: 192.168.0.1
Connect the device to the PC using a UTP cross lead CAT-5E or higher.
Start the web browser (recommended: Google Chrome, Mozilla).
In the address bar type in the IP address associated to the D-MATRIX-4S FTA, here 192.168.0.2; the opening screen is displayed shown in figure 1,
requesting the access data. Type the username and password (here the factory settings):