Specifications
Specifications are subject to change without notice.
Specification
Details
Dimensions
19.7 x 9.5 cm (7.75 x 3.75 in.)
Weight
335 g (0.75 lb) without batteries; 430 g (0.95 lb) with
four AA alkaline batteries
Meter enclosure
IP67, waterproof to 1 meter for 30 minutes
Battery enclosure
Water resistant to 0.6 m (2 ft) for 15 seconds
Power requirements
AA Alkaline or rechargeable Nickel Metal Hydride
(internal)
(NiMH) batteries (4); battery life: up to 200 hours
Power requirements
Class II, external power adapter: 100–240 VAC, 50/60
(external)
Hz input; 4.5 to 7.5 VDC (7 VA) output
Meter protection class
Class I
Storage temperature
–20 to +60 °C (–4 to +140 °F)
Operating temperature
0 to +60 °C (32 to 140 °F)
Operating humidity
90% (non-condensing)
5-pin input connector
M12 connector for IntelliCAL
8-pin input connector
The 8-pin connector enables USB and external AC
power connectivity
USB/DC adapter
Peripheral and host
Data memory (internal)
500 results
Data storage
Automatic in Press to Read mode and Interval Mode.
Manual in Continuous Read Mode.
Data export
USB connection to PC or USB storage device (limited
to the storage device capacity). Transfer entire data log
or as readings are taken.
Connections
Integrated USB type A (for USB flash memory device,
printer, keyboard) and Integrated USB type B (for PC)
Specification
Temperature correction
Measurement display
lock
Keyboard
General information
Revised editions are found on the manufacturer's website.
Expanded manual version
For additional information, refer to the CD for an expanded version of this
manual.
Safety information
Please read this entire manual before unpacking, setting up or operating
this equipment. Pay attention to all danger and caution statements. Failure
to do so could result in serious injury to the operator or damage to the
equipment.
Make sure that the protection provided by this equipment is not impaired,
do not use or install this equipment in any manner other than that specified
in this manual.
™
probes
Use of hazard information
Indicates a potentially or imminently hazardous situation which, if not avoided, will
result in death or serious injury.
Indicates a potentially or imminently hazardous situation which, if not avoided,
could result in death or serious injury.
Indicates a potentially hazardous situation that may result in minor or moderate
injury.
Details
Off, automatic and manual (parameter dependent)
Continuous measurement, Interval or Press to Read
mode. Averaging function for LDO probes.
External PC keyboard connector via USB/DC adapter
D A N G E R
W A R N I N G
C A U T I O N
English 3