INDICATIONS ON THE DISPLAY (D1)
Start up display
Shown for 2 seconds:
SL324E
Indicates the dip-switch setting
version
Alarm indications
System not programmed
You have to enter the programming mode to program the
system
Out of position
When carrying out an installation you will have to enter programming
in order to program the gate travel distances. During normal operation
automatic repositioning
take place (see page 19). In this case any commands received (TA,
TC, TAL or TD) will automatically start this procedure.
Caution! The gate moves automatically without waiting
for a command.
Block during encoder programming
This happens when an N.C. contact is activated (TB, FTCI, CSP)
during encoder programming or automatic repositioning. Once the
passive state of the security devices has been reset the gate will
start moving again automatically. It also happens if a blackout occurs
during programming.
Safety test error
Check the condition of the safety devices and make sure that the alarm
cuts in when an obstacle interferes with the beam (the relative LED will
switch off). In case of anomalies replace the damaged safety device
or bridge the contact and disactivate the safety test (dip 7).
Motor feed error
This occurs when the programmer sends a command to the motor and
nothing happens (the motor doesn't move). Check the motor faston
give another opening or closing command. If the motor still doesn't
move you are faced with either a mechanical problem or a problem
with the programmer.
A command was received with the motor released
This error normally appears when you have given a command and the
motor is released. If it occurs during normal motor operation it means
that there is a problem with the encoder signals. Check the relative
connections and carry out automatic repositioning (pag. 19).
Encoder direction error
The gate movement direction is different from the encoder setting (e.g.
the gate moves in the closing direction while the program is carrying
out the opening stage). Check the motor power supply connections
and the setting of dip 8.
Current sensor error
When the gate is not moving this symbol means there is a
problem with the current sensor.
Motor error
These symbols mean there is a problem with the motor
control relays
Operational indications
_41
F1
F3
22
Pause time programming
Automatic programming under way
Serial line (CSER) active
(only for diagnostics)
Opening stage
Block
Pause for automatic reclosing (if activated)
Closing stage
Current sensor updating (only during programming)
Opening + compensation sensor
Closing + compensation sensor
Test mode
Battery mode with a fully charged battery
Battery mode with an undercharged battery
Block caused by a completely discharged battery