IMPORTANT REMARKS
READ THE FOLLOWING REMARKS CAREFULLY BEFORE PROCEEDING WITH THE INSTALLATION. PAY PARTICU-
LAR ATTENTION TO ALL THE PARAGRAPHS MARKED WITH THE SYMBOL
INSTRUCTIONS COULD COMPROMISE THE CORRECT WORKING ORDER OF THE SYSTEM AND CREATE DANGER
SITUATIONS FOR THE USERS OF THE SYSTEM.
TRICAL EQUIPMENT
in force. All materials used must be approved and must suit the environment in
which the installation is situated.
technicians.
i.e. for the automation of sliding gates
to 3000 kg.
sageway. Any non authorised modifications are to be considered improper and
therefore dangerous.
Caution! The installation of both anti-derailment buffers
is absolutely obligatory.
IMPORTANT SAFETY INSTRUCTIONS
It is the responsibility of the installer to make sure that the following public safety
conditions are satisfied:
1) Ensure that the gate operating installation is far enough away from the main
road to eliminate possible traffic disruptions and that the size of the gate, the
distance from the road and the work cycle speed can in no way interfere, causing
possible traffic hazards.
2) The motor must be installed on the inside of the property and not on the public
side of the gate. The gates must not open onto a public area.
3) The gate operator is designed for use on gates through which vehicles are pass-
ing. Pedestrians should use a separate entrance.
4) The minimum controls which may be installed are OPEN-STOP-CLOSE, these
controls must be installed at a height between 1,5 and 1,8 m and in a location
not accessible to children. Controls installed externally must be protected by a
safety device inhibiting unauthorised use.
5) The gate must be in full view when it is operating therefore controls must be
situated in a position where the operator can see the gate at all times.
6) At least two warning signs (similar to the example on the right) should be placed,
where they can be easily seen by the public, in the area of the
system of automatic operation. One inside the property and one
on the public side of the installation. These signs must be indelible
and not hidden by any objects (such as tree branches, decorative
fencing etc.). Make sure that the end-user is aware that children
and/or pets must not be allowed to play within the area of a gate
installation. If possible include this in the warning signs
7) A correct earth connection is fundamental in order to guarantee
the electrical safety of the machine
8) Before carrying out any cleaning or maintenance operations make sure the power
is disconnected at the mains, the motor power cables are disconnected and the
batteries have been disconnected.
9) If you have any questions about the safety of the gate operating system, do not
install the operator. Contact your dealer for assistance.
TECHNICAL DESCRIPTION
- Mains power supply 230 Vac.
- Motor powered with a maximum voltage of 35 Vdc.
- Upper cover in highly resistant shock-proof plastic.
- Integrated lower cover in die cast aluminium containing a never ending
screw and double reduction lubricated with permanently fluid grease.
- Irreversible reduction system with a key operated manual release mechanism.
- The incorporated electronic programmer contains the power stage, the logic
control, battery charger and the radio receiver decoding module. The power
supply is routed to the electronics card via a separate transformer which is
housed in the same container and is connected to the card by Faston clips.
- The system is fitted with electronic deceleration control which reduces the
stress caused by the gate inertia when it stops.
Accessories
106/CRENY
- Rack (20 mm x 30 mm) in glass fibre with upper
fastening slits (1 m).
106/CRENY1 - Rack (20 mm x 30 mm) in glass fibre with lower
fastening slits (1 m).
106/SLOAC
- Rack in galvanised steel (22 mm x 22 mm)
2 m to be welded.
106/SLOAC2 - Rack in galvanised steel (12 mm x 30 mm)
1 m with fastening slits.
950/XLBS
- Contact safety edge available in lengths of:
1,5 and 3,0 m maximum height 70 mm.
IMPORTANT REMARKS
INSTALLERS OF ELEC-
left or to the right of the pas-
Q
During the opening/closing manoeuvre check for correct operation and activate
the emergency stop button in case of danger.
During blackouts with a flat battery the gate can be released and manually
manoeuvred using the supplied release key (see manual release fig. 8).
Periodically check the moving parts for wear and tear and grease if required,
using lubricants which maintain their friction levels unaltered throughout time
and are suitable for temperatures of -20 to +70°C.
Eventual repair work must be carried out by specialised personnel using
original spare parts.
The appliance is not suitable for continuous operation and may only be oper-
ated using a duty cycle of 70%.
Before starting the installation make sure that the structure which is to be
WARNING
automated is in good working order and respects the local standards and
AUTOMATIC OPENING
regulations in force. To this end ensure that:
KEEP CLEAR
CHILDREN OR PETS MUST NOT
BE ALLOWED TO PLAY ON OR
NEAR THE INSTALLATION
a) photoelectric cells
b) contact safety buffer
- when the gate is closed a space of 50 mm D
14
. NOT READING THESE IMPORTANT
USER INSTRUCTIONS
Attention! Only for EU customers - WEEE marking.
This symbol indicates that once the products life-span has expired
it must be disposed of separately from other rubbish. The user is
therefore obliged to either take the product to a suitable differen-
tial collection site for electronic and electrical goods or to send
it back to the manufacturer if the intention is to replace it with a
new equivalent version of the same product.
Suitable differential collection, environmental friendly treatment and disposal
contributes to avoiding negative effects on the ambient and consequently
health as well as favouring the recycling of materials.
Illicitly disposing of this product by the owner is punishable by law and will
be dealt with according to the laws and standards of the individual member
nation.
PRELIMINARY CHECKS (fig. 1, pag. 2)
a distance of 2.5 m from ground level.
Protrusions on the gate surface which are not greater than 3 mm and have
rounded edges are acceptable.
If the surface of the gate is not smooth, the entire height up to 2.5 m from
the ground must be protected by two of the following devices:
B
must not exceed 15 mm.
C
ground, completely exposed and free of any imperfections which could
inhibit the correct movement of the gate.
be positioned on the upper part of the gate.
D
better still a pneumatic or photoelectric contact safety buffer.
open spaces, it must be protected in one of the following ways:
H
500 mm: no protection required;
H
500 and 300 mm
L
25 mm
M
H
300 mm
L
M
I
1.2 mm
with railings or bars is over 2.5 m above the ground.
IMPORTANT REMARKS
A
G
I
I
L
P
E
F
12 mm
2.5 mm
2