Description of unit
3.4
Technical data for PowrCoat units
Model Number
Cart
Wall
Pressure Ratio
Max. operating pressure
Max. air inlet pressure
Cycle rate per gallon / liter
Volume per double stroke
Max. volume flow @ Cycles per minute (CPM)
60 CPM
90 CPM
Fluid inlet / outlet
Inlet
Outlet
Hose connection
Approximate air requirement (SCFM) per gallon of output @ 116 PSI
(8.0 bar) air pressure
Air inlet
Max. sound pressure level
Weight
Cart
Wall
Max. viscosity
Dimensions L x W x H
Cart
19.75" x 18.5" x 40" (50.16 cm x 47 cm x 101.6 cm)
Wall
14.5" x 12" x 34.5" (36.8 cm x 30.5 cm x 87.6 cm)
Max. temperature of pre-heated coating material
Filter insert (standard equipment)
* Place of measurement: 1 m distance from unit and 1.60 m
above reverberant floor, 120 bar (12 MPa) operating pressure.
PowrCoat
PowrCoat 630
0533630C
0533630W
30:1
3480 PSI (240 bar)
116 PSI (8 bar)
63 / 16
60.8 cc (3.71 in3)
0.96 gal (3.63 l)/min
1.45 gal (5.49 l)/min
3/4" NPT (F)
3/8" NPT (F)
1/4" NPSM (M)
25 SCFM (0.71 m3/min)
3/8" NPT (M)
98 dB*
90 lbs (41 kg)
64 lbs (29 kg)
50.000 mPa·s
140º F (60º C)
60 mesh, 97 cm2 (15 In2)
GB
4.
Operation
This equipment produces a fluid stream at extremely
high pressure. Read and understand the warnings
in the Safety Precautions section at the front of this
manual before operating this equipment.
4.1
Setup
1. Make sure the siphon hose (fig. 5, 1) is connected to the fluid
section (2) and the bleed hose (3) is connected to the bleed
valve (4).
2. Thread the suction tube filter (5) onto the metal suction tube.
4
2
1
3. Lock the gun by flipping the trigger lock into lock position
(see spray gun manual).
4. Using a wrench, attach a minimum of 50' of 1/4" nylon airless
spray hose to the material outlet fitting (fig. 6, item 1) on the
pump. Tighten securely.
Make sure all airless hoses and spray guns are
electrically grounded and rated for at least 3500 PSI
(24 MPa) fluid pressure.
7
Operation
3
5
1