Fig. 9: Setting of the CO
good range
9.2.2

Normal range

9.2.3

Poor range

46
The CO
Press key shortly: + 100 ppm
Press and hold the key: Scroll values
The value can only be set up to the upper limit of
the "normal" range
The display changes automatically to the setting
of the upper limit of the normal range.
alarm at the
2
Preset upper limit:
1000 ppm
Setting range:
Upper range "Good" + 100 ppm (> 500 ppm) up to
9.900 ppm
All the CO
range are critical. The critical range must therefo-
re not be set.
value flashes.
2
Change the value with the ▲-key.
NOTE!
Confirm with the ●-key or the Ξ-key.
Follow the same procedure for setting the
normal range as described in chapter 10.2.1.
values that are above the normal
2
Press the Ξ-key or the ●-key to access the
display for switching the warning signal on/off.