Open the air inlet grille and take off air filter.
•
Clean the air filter with neutral detergent in lukewarm 40°C water
and allow to dry (not in direct sunlight).
•
Re-install the air filter into the inlet grille.
TROUBLESHOOTING
Troubles Possible Causes
The unit
•
Water full indicator
does not
lamp blinks and water
start
tank is full.
when
•
Room temperature is
pressing
higher than the setting
power
temperature.(Electric
button.
heating mode)
•
Room temperature is
lower that the setting
temperature.(Cooling
mode)
Suggested Remedies
•
Drain the water out of the
water tank.
•
Adjust the temperature.
The unit
•
The doors or windows
doesn't
are not closed.
cool
•
There are heat
enough.
sources inside the
room.
•
Hot air exhaust hose
is not connected or
blocked.
•
Temperature setting
is too high.
•
Air inlet in blocked.
Noisy.
•
The ground is not
level or not flat
enough.
•
The sound comes
from the flowing of the
refrigerant inside the
air conditioner.
E0 Code. •
Room temperature
sensor failed.
E1 Code. •
Condenser
temperature sensor
failed.
E2 Code. •
Water tank full.
Instruction manual
•
Make sure all the
windows and doors are
EN
closed.
•
Remove the heat sources
if possible.
•
Connect or clean the hot
air exhaust hose.
•
Reset the temperature.
•
Clean the air inlet.
•
Place unit on a flat, level
ground if possible.
•
Replace room
temperature sensor.
•
Replace condenser
temperature sensor.
•
Please empty the water
tank.
11