6.11 Restoring factory settings (reset)
Resetting the password for "installer" access
1. Turn off the camera.
2. Press and hold the "PW reset" button on the camera.
3. Now connect the power supply to the camera (using 2-pin power supply or Power over
Ethernet) and hold down the "PW reset" button for a further 60 seconds.
Reset all camera settings
1. Turn off the camera.
2. Press and hold the "Reset" button on the camera.
3. Now connect the power supply to the camera (using 2-pin power supply or Power over
Ethernet) and hold down the "Reset" button for a further 60 seconds.
6.12 Changing the dome
IPCB34500 / IPCB74500
If required, there is a tinted dome available for the IP dome cameras specified (ABUS item
number TVAC31065).
The dome is installed as follows:
1. Remove the dome from the camera by loosening the four fixing screws (dome with dome
ring).
2. Remove the remove fixing screws on the underside of the dome.
3. Remove the dome from the dome ring.
4. Insert the tinted dome into the dome ring.
5. Place the fixing ring on the underside of the dome ring and screw in the four fixing screws.
65