4.0 FLASHLIGHT MODULE
On HPA702L, HPA702LG and HPA703XP models, a flashlight module in LED technology is assembled, that
joins together a longer time and reduced consumptions, allowing a longer battery autonomy. The module has
two additional signalling LEDs available.
Red LED
Basic version (HPA702L, HPA702LG)
The System Status RED LED signals the TC signal logic condition:
Off: TC signal present, inactive system;
Blinking: TC signal absent, active system;
The Failure YELLOW LED shows the storage of the first detected
anomaly in a chronological order (only with TC signal present,
namely with inactive system) by means of a short blinking every 2 s.
It is possible to obtain the detail about failure types (that are signalled
by different blinking), by keeping the "TEST" jumper (present on the
siren module – see paragraph 3.0) short-circuited.
The table shows the different blinking and their meaning.
Memory deletion occurs with the following TC transition (system
activation).
Note: if such luminous signalling are not wanted, disconnect the respective wires from terminals L1 and L2 of
the siren module (see paragraph 3.0).
5.0 PROTECTION MODULE
The HPA703XP siren is equipped as series with a protection module (optional for HPA702L and HPA702LG
versions) managed by a microprocessor that is able to detect tampering attempts with foam, drilling, thermal
attacks (fixed threshold in combination with thermal-speed analysis).
TX and RX elements of foam-preventing protection
LED
Yellow LED
Red LED
28/44
High efficiency version (HPA703XP)
Number of
blinking
1
2
3
4
NC contact output
Is
recommended
protection module output serially with
the tamper-preventing contact or to an
"24h" input in the central unit.
HPA701 - HPA702L - HPA702LG - HPA703XP
Yellow LED
Meaning
Battery discharged
Failed horn
Failed flash
Failed protection
module (if present)
to
connect