random flow" – random current flow
"
The random flow occurs when the sequential pump circuit and the pulse operation are switched on simultaneously. It
always occurs when a fixed "pulse flow" pulse frequency, or "random flow" is set.
In the field "mode", click on the "sequential" button.
Set the "sequential" switching time by clicking on 1 to 10 sec.
In the field "power control", the pump performance can be set to "low power" and "high power" by clicking on the
channels "channel" 1 to 4. The number zero "0" means pump not operating. The lowest possible setting is 20%, and
the maximum adjustable setting is 100%.
The pulse frequency "pulse flow" can be set from 0.3 to 8.0 sec.
Result:
Pump 1 will start, later on pump 2, then pump 3, then pump 4, and subsequently all four pumps will stop.
At the same time, the pumps will pulse in the pulse frequency "pulse flow" and reproduce an uneven current flow
pattern.
If the night mode function "night mode" is enabled, this will interrupt the pulse operation for the programmed time
interval, for example, from 9:00 p.m. to 9:00 a.m., during which all pumps will remain in the "low power" setting. In the
morning after 9 a.m., the selected pulse operation of the pump will then start.
If the "wavecontroller" function is activated, the outputs 3 and 4 will be used, the sequential pump circuit "sequential"
will then only be active for outputs 1 and 2.
106
107