TECHNICAL DATA

MODEL
TYP
OUTPUT
max.
(1)
min.
FUEL
Gas pressure at maximum delivery.
OPERATION
STANDARD APPLICATIONS
AMBIENT TEMPERATUR
COMBUSTION AIR TEMPERATURE
ELECTRICAL SUPPLY
FAN MOTOR
(star-delta starting for RS400 and RS500)
IGNITION TRANSFORMER
ELECTRICAL POWER CONSUMPTION
ELECTRICAL PROTECTION
CONFORMITY TO EEC DIRECTIVES
NOISE LEVELS
(3)
APPROVAL
Reference conditions: Ambient temperature 20°C - Barometric pressure 1000 mbar - Altitude 100 m a.s.l.
(1)
Pressure at pressure switch test point 20)(A)p.12 with zero pressure in the combustion chamber and maximum burner output.
(2)
Sound pressure measured in manufacturer»s combustion laboratory, with burner operating on test boiler and at maximum rated output.
(3)

ACCESSORIES

(optional)
OUTPUT POWER REGULATOR KIT:
rates between the low and high flame output position, thus ensuring stable operating conditions in terms of temperature or pressure. Two compo-
nents should be ordered: • Power regulator to install to the burner; • probe to install to the boiler.
PARAMETER TO BE CHECKED
Temperature
Pressure
• KIT AZL (display and operating unit)
• INFRARED SENSOR KIT QRI
• PRESSURE SWITCH KIT (for leak detection control)
• KIT SOFTWARE INTERFACE
GAS TRAIN ACCORDING TO REGULATION EN 676
Note.
Riello S.p.a. declines all responsibility for the addition of safety devices not provided for herein.
kW
kW
Gas: G20/G25
mbar
(2)
°C
°C max
rpm
V
kW
A
V1 - V2
I1 - I2
kW max
dBA
class 3 (EN 676)
CE
Under modulating operation, the burner automatically adapts to one of an infinite number of firing
Range
- 100...+ 500°C
0...2,5 bar
0...16 bar
RS 300/E BLU
849 T1
1350 ... 3800
500
NATURAL GAS: G20 (methane) - G21 - G22 - G23 - G25
18 / 26
Continuous / Intermittent
Boilers: water, steam, diathermic oil
0 - 40
60
3N ~ 400 / 230V +/-10% 50 Hz
2900
230/400
4,5
15,8 - 9,1
6
IP 54
98/37 - 90/396 - 89/336 - 73/23
82
0085 BO 0341
PROBE
Type
PT 100
Output probe
4...20 mA
Code 3010355
Code 3010354
Code 3010344
Code 3010388
: see page 22.
8
RS 400/E BLU
RS 500/E BLU
850 T1
1800 ... 4500
800
33.4 / 38.7
2900
400/680
7,5
16 - 9
230 V - 1 x 8 kV
1 A - 20 mA
10
85
0085 BO 0341
POWER REGULATOR
Code
Type
3010110
RWF40 BASIC
3010213
RWF40 HIGH
3010214
856 T1
2500 ... 5170
1000
38,2 / 55,8
2900
400/680
9,2
18 - 10,5
11
88
Code
3010356
3010357