Cleaning metal grease filters
The metal grease filters can be cleaned in hot de-
tergent solution or washed in the dishwasher. They
• Remove grease filters.
should be cleaned every 2 months use, or more
frequently if use is particularly heavy.
• Open the Panel by pulling it down.
• Remove the filter, pushing the lever towards the back
of the unit and at the same time pulling downward.
• Wash the filter without bending it, leave it to dry
thoroughly before replacing (if the surface of the filter
changes color over time, this will have absolutely
• Screw the Frame into place
no effect on its efficiency).
• Replace, taking care to ensure that the handle
faces forward.
• Cleaning in dishwasher may dull the finish of the
metal grease filter.
• Close the Panel.
Replacing Activated Charcoal Filter
The Activated Charcoal Filters are not washable
and cannot be regenerated, and must be replaced
approximately every 4 months of operation, or more
frequently with heavy usage.
• Open the Panel by pulling it down.
EN
• Remove the Filter, pushing it towards the back of
the unit and at the same time pulling downward.
• Remove the saturated Activated Charcoal Filters,
as indicated (A).
• Fit the new Filters, as indicated (B).
• Replace, taking care to ensure that the handle
faces forwards.
• Close the Panel.
CAUTION: When used in recirculation mode, to Re-
duce the Risk of Fire and Shock use only conversion
kit Model FILTER 1.
• LED lights must be replaced by Faber factory
authorized service.
14
fixing pin lever.
using the 6 screws 12f, re-
connect the wires to the
Commands and Light, re-
place the metal grease filter
and the Panel.