Hilti HIT-MD 1000 dispenser
The Manual Dispenser Hilti HIT-MD1000 together with
the Hilti HIT-ICE cartridges forms a complete injection
system. Before use, read also the safety precautions and
instructions for use on the HIT-ICE cartridge and check
the expiration date on it. Minimum product tempera-
ture must be maintained during use.
Hilti HIT-ICE System
³ Dispenser Hilti HIT-MD1000
· Cartridge Hilti HIT-ICE
» Mixer Hilti HIT-M2
Cradle
Piston rods
Locking lever
Operation:
Hold cartridge and unscrew the cap.
Remove the safety red insert.
Screw on the mixer tightly. Use only Hilti HIT-M2
mixers.
Press locking lever on dispenser while pulling back
piston rods as far as it will go.
Put Hilti HIT-ICE cartridge with attached mixer into
the MD1000 dispenser.
Discard the first 2 trigger pulls of adhesive mor-
tar from the mixer, as it is not suitable for making
fastenings. Likewise, after changing a mixer, the
first trigger pull should be discarded.
The hole must be filled with mortar without forming
air pockets. To achieve this, insert the mixer as far
as the base of the hole (use an extension for deep
holes) and slowly withdraw the mixer, step by step,
after each pull of the trigger. Refer to Hilti literature
for specific setting details.
Press the locking lever after the hole has been filled
with mortar. This releases the pressure on the car-
tridge and no further adhesive mortar flows from
the mixer.
To remove the cartridge from the dispenser the pis-
ton rods must be first pulled into the rearmost posi-
tion while pressing the locking lever.
G The mixer must be changed after the gel time has
elapsed.
G Always release the locking lever before changing mix-
ers.
Wear protective gloves
2
Printed: 07.07.2013 | Doc-Nr: PUB / 5103000 / 000 / 00
Wear eye protection
G Partly used cartridges can be stored with the mixer
screwed on.
Cleaning and maintenance:
Fresh spots and deposits of mortar in the working sec-
tion of the dispenser should be removed immediately.
Cured mortar can only be removed mechanically. Pro-
tect dispenser from dust and lightly oil rods regularly.
Precautions:
G MD1000 should be used exclusively with Hilti HIT-
ICE cartridges
G Wear gloves and goggles when using the dispenser
G Do not disassemble the dispenser
G This product is for industrial use only
G Observe information on the HIT-ICE cartridge (Safe-
ty data sheets furnished upon request by contacting
Hilti, Inc.).
Manufacturer's warranty – tools
Hilti warrants that the tool supplied is free of defects
in material and workmanship. This warranty is valid so
long as the tool is operated and handled correctly,
cleaned and serviced properly and in accordance with
the Hilti Operating Instructions, and the technical sys-
tem is maintained. This means that only original Hilti
consumables, components and spare parts may be
used in the tool.
This warranty provides the free-of-charge repair or
replacement of defective parts only over the entire lifes-
pan of the tool. Parts requiring repair or replacement
as a result of normal wear and tear are not covered by
this warranty.
Additional claims are excluded, unless stringent
national rules prohibit such exclusion. In particular,
Hilti is not obligated for direct, indirect, incidental
or consequential damages, losses or expenses in
connection with, or by reason of, the use of, or inabil-
ity to use the tool for any purpose. Implied warranties
of merchantability or fitness for a particular purpose
are specifically excluded.
For repair or replacement, send tool or related parts
immediately upon discovery of the defect to the address
of the local Hilti marketing organization provided.
This constitutes Hilti's entire obligation with regard to
warranty and supersedes all prior or contemporane-
ous comments and oral or written agreements con-
cerning warranties.

Publicité

loading