Honeywell kromchroeder KROMS 5 BP Instructions D'installation, D'utilisation Et De Maintenance page 5

Table des Matières

Publicité

IA-211 Rev.1 Ed. 0
15.03.2018
ES – GB - FR
www.kromschroeder.es
Kromschroeder S.A.
HOSPITALET DE LL. (BARCELONA)
0099
ESPAÑA
99CT971
kW (H
)
Pmbar
s
BE-CH-CZ-DE
20-300
ES-FR-GB-GR
0,55-4,8 40-346 g/h
3P
20-200
HU-IE-IT-NL
PL-PT-SI
20-150
/
04.2018
Cat I
Fig. 2
ES
3.1.2 Encendido
Conecte el radiador a la canalización de gas por medio de
una válvula de corte a la presión máxima de conexión que
permita el modelo (ver placa de características del
aparato, apartado presión utilización en mbar). A
continuación encienda el radiador acercando una llama a
la ventana de encendido situada en la parte trasera del
cono exterior. Presionar a fondo el pulsador de la válvula
termo-eléctrica. Una vez encendido mantener el pulsador
presionado a fondo como mínimo 20 segundos, durante
3P
los cuales la combustión del gas calienta el termopar y
éste genera corriente eléctrica, manteniendo abierta la
válvula de seguridad permitiendo el paso del gas.
Transcurrido este tiempo soltarlo suavemente. El
quemador irá tomando progresivamente una coloración
rojo-cereza emitiendo radiación infrarroja.
En caso de que el aparato no se encendiera, repetir la
operación de encendido desde el principio.
Una vez transcurrido el periodo de encendido y tras liberar
el pulsador de la válvula de seguridad, el radiador pasará
a potencia máxima, ya que durante la maniobra de
encendido, la válvula de seguridad tiene un sistema de
limitación de potencia inferior a 6 kW (según EN 419),
según modelo, ver tabla de características.
Régimen de funcionamiento
Cuando hay demanda de calor, un sistema central o
individual de regulación proporciona la presión máxima de
utilización. El cono exterior, que forma la cámara de
combustión, alcanza una coloración rojo-cereza. En estos
momentos la temperatura del cono está en torno a los 800º
C, emitiendo radiación infrarroja hacia el suelo.
En estas condiciones el reflector distribuye la radiación
infrarroja alcanzando un área circular cuya dimensión es
función de la altura de suspensión y el modelo de aparato.
El aparato irá modulando la intensidad de radiación en
función de la demanda de calor, mediante el sistema de
regulación individual o central que actúa sobre la presión
de gas de la línea.
GB
3.1.2 Ignition
Connect the brooder to the gas supply using the shut-off
valve at the maximum connection pressure permitted by
the model (see the system's specification plate, in the
section on usage pressure in mbar). Then ignite the
brooder by applying a flame to the ignition window, on the
rear section of the outer cone. Press the button on the
thermoelectric valve as far as it will go. Once lit, keep the
button pressed down fully for at least 20 seconds, during
which time the gas combustion heats up the thermocouple;
this generates an electric current, keeping the safety valve
open and allowing the gas to flow through. After 20
seconds, gently release the button. The burner will take on
a progressively cherry-red hue, emitting infrared radiation.
In the event that the system does not light, repeat the
ignition procedure from the beginning.
When the ignition period has elapsed and the safety valve
button has been released, the brooder will go on to full
power, since during the ignition procedure, the safety valve
is fitted with a system which limits power to below 6 kW
(compliant with the EN 419 standards), depending on the
model (see specifications table).
Operating conditions
When there is demand for heat, a central or individual
regulation system supplies the maximum usage pressure.
The outer cone, which forms the combustion chamber, will
take on a cherry-red hue. At this time, the temperature in
the cone is around 800°C, and infrared radiation is emitted
towards the ground.
Under these conditions, the reflector distributes the
infrared radiation, covering a circular area, the size of
which will depend on the suspension height and model of
the system.
The system will modulate the intensity of the radiation
depending on the heat demand, through the individual or
central regulation system, which acts on the gas pressure
in the tube.
-5-
Pág. 5 de 16
FR
3.1.2 Allumage
Raccordez le radiant à la conduite de gaz au moyen du
robinet d'arrêt à la pression maximale de raccordement
permise par le modèle en question (voir plaque
signalétique de l'appareil, section pression d'utilisation en
mbar). Allumez ensuite le radiant en approchant une
flamme de la fenêtre d'allumage située dans la partie
arrière du cône extérieur. Appuyez à fond sur le bouton de
la vanne thermoélectrique. Après l'allumage, maintenez le
bouton enfoncé à fond pendant au moins 20 secondes.
Pendant ce temps, la combustion du gaz chauffe le
thermocouple et ce dernier génère un courant électrique
qui permet de maintenir la vanne de sécurité ouverte pour
permettre le passage du gaz. Ensuite, relâchez le bouton
en douceur. Le brûleur prend progressivement une couleur
rouge vif et émet alors un rayonnement infrarouge.
Si l'appareil ne s'allume pas, recommencez l'opération
depuis le début.
Une fois la phase d'allumage terminée et après avoir
relâché le bouton poussoir de la vanne de sécurité, le
radiant se met en puissance maximale ; en effet, pendant
la manœuvre d'allumage, la vanne de sécurité est soumise
à un système de limitation de la puissance à moins de
6 kW (conformément à la norme EN 419), en fonction du
modèle (voir tableau de caractéristiques).
Régime de fonctionnement
Lorsqu'il y a demande de chaleur, un système central ou
individuel de réglage fournit la pression maximale de
service. Le cône extérieur qui constitue la chambre de
combustion prend une couleur rouge vif. La température
du cône est à ce moment de l'ordre de 800 °C, et celui-ci
émet un rayonnement infrarouge vers le sol.
Dans ces conditions, le réflecteur distribue le rayonnement
dans une zone circulaire dont le diamètre dépend de la
hauteur de suspension et du modèle d'appareil.
L'appareil module l'intensité du rayonnement en fonction
de la demande de chaleur, grâce au système de réglage
individuel ou central qui agit sur la pression du gaz de la
ligne.

Publicité

Table des Matières
loading

Table des Matières