Flange Mounting - Emerson AVENTICS RAK Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 59
Fig. 11: Flange mounting
Table 5: Dimensions, flange mounting
For size
A
1
30
2
37
3
42
4
50
5
64
6
80
7
110
AVENTICS
6.6

Flange mounting

Fit the flange mounting to the front end of the rotary actuator
1.
using screws supplied. The flange for size 2 and 3 can be fitted
in steps of 120
Attach the flange to a base by using suitable screws or bolts.
2.
See Table 5, screw (C).
Tighten the screws gradually to avoid strain. See Table 5 for
3.
tightening torque.
B
C
D
24
3.4
2.0
30
3.4
2.5
34
3.5
3.2
41
5.5
3.6
52
5.5
3.6
64
7.0
4.5
88
9.0
6.0
| RAK | R402005099–BDL–001–AB
°
from the reference position.
Screw
E
(C)
14.0
M3
16.5
M3
19.8
M3
24.9
M5
27.9
M5
35.0
M6
47.5
M8
47
Tightening torque
(class 8.8)
1.2 Nm
1.2 Nm
1.2 Nm
6 Nm
6 Nm
10 Nm
24 Nm

Publicité

Table des Matières
loading

Table des Matières