6. Place the unit into position over the mounting holes with
the electrical conduit(s) positioned through the channel and
center mounting hole(s).
7. Secure the unit to the mounting surface with 1/4" x 1-1/2"
(6 x 38 mm) hex bolts and nuts provided.
8. Install non-adjustable stand covers onto stands by
snapping into place.
Non-Adjustable
Stand
Cover
Bolt
Installing Unit to Countertop
NOTE: GR2A series units mounted to a metal surface may
require a backing plate installed to the underside of the
surface in order to increase unit stability. (Backing plate
not supplied by Hatco).
Dual Mounting
When mounting units side-by-side, a space not less than 3"
(76 mm) must be maintained between units.
Pass-Through
If a pass-through area is 12"–16" (305–406 mm) deep, a standard
wattage or high wattage single unit can be used. For a 18"–24"
(457–610 mm) deep pass-through area, a dual unit in either
standard or high wattage is recommended. Installation of multiple
units must have a minimum spacing of 3" (76 mm) between units.
Form No. GR2AM-1116
Nut

Electrical Requirements

Foodwarmers equipped with incandescent lights that
require a circuit breaker larger than 20 amps for the heat
element must have a separate circuit breaker for the
incandescent lights that is 20 amps or less.
Refer to the SPECIFICATIONS section for specific model, watt,
and amp ratings.
Install a supply wire rated for 194°F (90°C). The remote control
box (RMB) provides a 1/2" and 3/4" knockout, 6" (152 mm) long
pigtail leads and a separate grounding terminal or screw in the
wiring compartment. Use wire nuts (not supplied) for connecting
supply wires.

Power Supply

Install supply wire and connectors suitable for at least 194°F
(90°C).
• Use a minimum of No. 14 AWG copper wire for individual
circuits up to 15 amps.
• Use a minimum of No. 12 AWG copper wire for individual
circuits 15 to 20 amps.
• Use a minimum of No. 10 AWG copper wire for individual
circuits 20 to 25 amps.
• Use a minimum of No. 8 AWG copper wire for individual
circuits 25 to 30 amps.
NOTE: Refer to the wiring diagram supplied with the unit and
specifications label attached to the unit for specific
electrical information.