5.2. PROTECTION AND SIGNIFICANT CAUTION
All live wires or parts are electrically isolated
from the earth. However, there is an additional
safety feature, which composes of all accessible
conducting parts being connected to an earth wire
so that these parts cannot become hazardous
if the main isolating system fails.
EN

6. DESCRIPTION AND USE OF MOTOR-DRIVEN PUMP

6.1. DESCRIPTION
SUBMERSIBLE MOTOR-DRIVEN
Name
PUMPS
Model
DEMINY
(see data plate)
6.2. INTENDED USE
The motor-driven pumps are intended to move water
containing solids in suspension as described in para. 7.1.
6.3. UNINTENDED USE
Pumps are not suitable for:
-
treating liquids other than water;
-
treating water with a pH not falling into the range
specified at 7.1;
-
treating seawater (with the exception of the versions
in AISI316);
-
treating flammable liquids and hazardous liquids in
general;
-
coming into contact with food products;
-
being used in structures intended for living organisms
(swimming pools, aquariums, fish farms, etc.);
-
being used differently from that specified in paragraph
6.2 "Intended use".

7. SPECIFICATIONS

The manufacturer reserves the right to modify technical
specifications to improve or update its products without
prior notice.
8
7.1. DEMINY SERIES PUMP SPECIFICATIONS
Maximum relative density of liquid treated
pH of liquid treated
Temperature of liquid treated
immersion depth
50DEMINY51.1M
50DEMINY51.1T
50DEMINY51.5M
50DEMINY51.5T
80DEMINY52.25M
80DEMINY52.25T
80DEMINY53T
80DEMINY54.5T
100DEMINY55.5T
100DEMINY57.5HT
100DEMINY57.5T
100DEMINY59.5T
100DEMINY512.5T
7.2. MOTOR SPECIFICATIONS
Pumps with single-phase motor must be piloted
by an electrical panel fitted with start-up and
operating condensers and start-up relay.
Condensers and relay for single-phase motors
Electromechanical circuit
breaker
(50DEMINY51.1)
Capacitor (80DEMINY52.2)
Ratings
Protection from
overheating
Maximum number of
start-ups per hour
Tolerance on
voltage
Tolerance on
frequency
Motors of the DEMINY (80DEMINY, 100DEMINY) pumps
can be piloted with inverters/VFD.
1.1
5 ÷ 7
[°C]
0 ÷ 35
minimum
[m]
0.130
maximum
[m]
15
[mm]
Ø10
Cs
[μF]
50
Cr
[μF]
30
[μF]
80
Cr
V
450
See plate data
Thermal probe
(to be connected
to the panel)
15
± 6%
± 3%