7.2 Changing - creating a program
(Start menu, CE level)
00: ATTENTION! If required, it is recommended to perform only minor
changes of the default parameters of the individual materials.
01: Set main switch (01) to On.
02: Select Create/change data in the menu using the yellow keys
Menu
(11/12).
Menu
03: Confirm by pressing Enter (16) once.
Enter
04: Use the yellow keys (11/12) to select the respective program.
Menu
Menu
05: Confirm by pressing Enter (16) once.
Enter
06: Confirm by pressing Enter (16) two times.
Enter
07: Use the blue keys (13/14) to change the value.
+/-
08: Confirm by pressing Enter (16) once.
Enter
09: Use the yellow keys (11/12) to access the next parameters step by
step and process as described under item 06: to 09:
1: Set temperature
2: Heating time
3: Pressure time
4: Speed:
5: Force:
6: Dataset name:
10: Press CE key (15) once. .............................
CE
11: Press CE key (15) one more time and you access the Start menu,
CE
CE level.
20
[° C ]:
0-400
[min]:
0-255
[s]:
0-255
0-9
0-255
A-Z+special characters
bredent GmbH & Co. KG · Weissenhorner Str. 2 · 89250 Senden · Germany · T: +49 7309 872-441 · F: +49 7309 872-444
www.bredent.com · @: info@bredent.com
Display and help
The sequence of entries must be strictly adhered to to ensure correct
storage of the values.
The company logo of bredent is displayed for approx. 7 sec; then the
menu selection is displayed.
Create/change data.
Dataset – Number <Name> is displayed.
A maximum of 30 datasets can be stored.
The display changes to the first menu parameter
Set temperature [°C ]: 0
After pressing for the first time, the value is highlighted and flashes
after pressing for the second time.
The value stops flashing and remains highlighted. The entered value is
not retained unless the 'Enter' key is pressed.
Temperatures above 400°C can not be entered. The display returns to
400°C.
If temperatures below room temperature are entered, the program
sequence will be blocked; the value should be approx. 5-10°C higher.
Use the blue cartridge ejecting keys (06) (08) to select the respective
character position in the word.
Then use the blue keys (13/14) to select the individual small and
+/-
capital letters, special characters and numbers. The cursor jumps to
the next position in the word if no further entry is made.
If required, use the blue keys (06/08) for corrections.
Only after pressing the CE key, all entries will be permanently
CE
stored.
You will return to operating level 1.