DC and AC voltages
8 V DC ranges
resistance(1)
100mV
1V
3V
10V
30V
100V
300V
1000V
(1) Internal R = 20kΩ/V on all ranges (except the 1000V range - R int. = 6,32kΩ/V).
(2) Internal R = 6,32kΩ/V.
DC and AC currents
5 A DC ranges
Voltage drop at
the terminals (1)
50µA (2)
1mA
10mA
100mA
1A
(1) R fuse = 10Ω
(2) Position common to the 100mV DC range
(3) Position common to the 3V AC range

2. SPECIFICATIONS

6 V AC ranges
Internal
2kΩ
20kΩ
63,2kΩ
3V
200kΩ
10V
30V
632kΩ
2MΩ
100V
300V
6,32MΩ
6,32MΩ
1000V
6 A AC ranges
150µA (3)
100mV
270mV
0,3mA
3mA
411mV
1,3V
30mA
500mV
300mA
3A
21
Internal
Measurement of
resistance (2)
dB level
20kΩ
-10 to +12dB
63,2kΩ
on the 3V AC
200kΩ
range
632kΩ
(level 0dB
2MΩ
1mW.600Ω)
6,32MΩ
Voltage drop at
the terminals (1)
3V
700mV
850mV
1,15V
900mV
1,6V

Publicité