Short overloads (5 seconds)
220V rms : on the 1V - 3V - 10V DC ; 3V - 10V AC and x 1kΩ ranges.
380V rms : on the 30V and 100V DC and AC ranges.
600V rms : on the 300V DC and AC ranges.
1500V rms: on the 1000V DC and AC ranges.
Power supply
One battery 1.5V type R6.
The calibration potentiometer enables the use of batteries from 1.7V to 1.3V.
Note : we recommend using an alkaline battery for intensive use of the x 1Ω range.
Adherence to standards
Dual insulation equipment.
IEC 1010
Earth test voltage.
- 6kV between the case and the terminals short-circuited.
- 600V rms max in relation to the earth.
Distance in the air and leakage lines ≥ 13mm.
IEC 529
IP40; IK03.