„ Connect the leads to the multimeter and connect in parallel to the circuit to be
tested.
„ Set the switch to the Hz function.
„ Digital reading: automatic range selection, kHz is displayed, read the measured value.
If necessary, press the following keys:
- HOLD to hold in memory
-
for display backlighting
No analogue reading: the needle stays on zero.
kHz
Max reading
Accuracy
Permitted overload

11. GENERALS SPECIFICATIONS

11.1 DIMENSIONS AND WEIGHT

„ 56 x 105 x 160 mm
„ 500 g

11.2 POWER SUPPLY

„ One battery 9 V (type 6F22 or 6LF22 alkaline)
„ Battery life: 300 hours on permanent use

11.3 ENVIRONMENTAL CONDITIONS

„ Temperature:
„ Relative humidity:
„ Altitude:

11.4 CONFORMITY WITH INTERNATIONAL STANDARDS

Electrical safety (NF EN 61010-1)
„ Double insulation:
„ Degree of pollution: 2
„ Installation category: III for rated voltage of 1000 V
„ Installation category: IV for rated voltage of 600 V
Electromagnetic compatibility: conforms to CE
Emission and immunity (NF EN 61326-1)
Mechanical protection
Degree of watertightness (NF EN 60529): protection index IP 53

10. FREQUENCES

4 kHz
3.999 kHz
- use: 0 to +55°C
- storage: -40 to +70°C
- use:10 to 90 % HR
- storage: 10 to 95 %HR
- use < 2000 m
40 kHz
39.99 kHz
1 % rdg ± 2 counts
1000 V
22
100 kHz
99.9 kHz