Nila
Fixed towel warmer for permanent installation.
Supplied complete with connection cable /with plug and wall
brackets with screws.
Supply voltage: 230 V AC. For Australia 230V-240V
Enclosure class IP 44.
This appliance is equipped with an all-pole switch with a contact
separation of 3 mm.
Nila R
As Nila, but with adjustable surface temp. 38-60ºC.
Nila Ti
As Nila, but the countdown timer is continuously adjustable from
2 to 8 hours, or continuous operation.
Muria
Swivelling towel warmers for permanent installation.
Supplied complete with connection cable /with plug and wall
brackets with screws.
Supply voltage 230 V AC. For Australia 230V-240V
Enclosure class IP 44.
This appliance is equipped with an all-pole switch with a contact
separation of 3 mm.
Muria R As Muria, but with adjustable surface temp. 38-60ºC.
Muria Ti As Muria, but the countdown timer is continuously adjustable from
2 to 8 hours, or continuous operation.
InstallatIon
PosItIonIng
On a towelwarmer, which is fixed and permanently connected, the frame
may protrude into zone 1, but then it must be positioned so that the switch
is located in zones 2 or 3, see figures 1-4. If the plug is used, the whole of the
towelwarmer must be positioned in at least zone 2. Since the towelwarmer is
reversible, the switch should be positioned facing away from the bath or show-
er. The recommended minimum dimensions to limiting surfaces in the vicinity
are indicated in figures 5-6. It is important to remember that the towelwarmer
is there to hang towels on and must not be used to hold on to.
To avoid injuries to small children the towelwarmer must be positioned so that
the lowest part is at least 600 mm above the floor.
asseMbly and connectIon
For the correct installation of radiators it is essential that the fixing of the
towelwarmer is carried out in such a way that it is suitable for intended use
and predictable misuse. A number of elements need to be taken into considera-
tion including the fixing method used to secure the towelwarmer to the wall,
the type and condition of the wall itself, and any additional potential forces or
weights, prior to finalising installation.
A residual current device of 30 mA is compulsory if the towelwarmer is installed
in a bathroom, shower or other wet areas.
Fit the towelwarmer on a vertical wall using the supplied screws. The minimum
recommended distances from adjacent boundary surfaces are shown in fig. 5
and 6. The coupling box and switch/knob must be at the bottom of the towel-
warmer.
The wall brackets for the Nila/Nila R/Nila Ti model can be repositioned to take
account of any tile joints, etc. Tighten the brackets from the rear using the screw
at the centre of the bracket before fitting the towel warmer to the wall; see fig.
3A.
The lower wall bracket of the Muria/Muria R/Muria Ti model can be adjusted
vertically within the range shown in fig. 6. The wall brackets are assembled at
the factory to provide sufficient swivel resistance and do not normally require
adjustment. Any necessary adjustment can be made with the screw inside the
bracket, as shown in fig. 3A.
towelwarMer wIth connectIon cable and Plug
Connect the towel warmer's connection cable to an earthed wall socket with
the plug.
towelwarMer wIth connectIon cable wIthout a Plug
Connect the towel warmer's 3-core cable to a suitable terminal box as follows:
Brown wire
= Live
Blue wire
= Neutral
Green/yellow wire
= Earth
The electrical installation must be done by an authorised electrician.
Model nIla/nIla r/nIla tI wIth concealed connectIon
The Nila/Nila R/Nila Ti model can be installed with concealed connection as an
alternative (not the Muria/Muria R/Muria Ti model). The centre of the wall out-
let for the connecting wires can be seen in fig. 7. The supplied backing washer
can be used here.
The connection box must be modified for installation with concealed connec-
tion. Start by removing the lid of the connection box by undoing the two screws
which hold the lid in place. Then disconnect the installed connection cable.
Remove wires A on the heating element and release the insert. Remove nut C
completely, using the supplied 21 mm hexagon socket, and rotate the under
part of the terminal box so that bushing D faces the wall, see fig. 8 for Nila and 9
for Nila R/Nila Ti, and then tighten nut C securely.
The electrical installation must be done by an authorised electrician.
InstallatIon wIth concealed connectIon wIthout backIng washer
Position the connection box so that the hole in bushing D centres the connection
cable, and then mark the screw holes on the wall brackets. Install the towel-
warmer.
InstallatIon wIth concealed connectIon wIth backIng washer
Centre the backing washer over the connection cable. If necess a ry, secure it to
the wall with adhesive. Offer up the towelwarmer, position the connection box
on the washer, and mark the screw holes on the wall brackets. Install the towel-
warmer.
connectIon
Pass the cable or equivalent through bushing D, ensuring that the sealing effect
is maintained. Connect the incoming wire to terminal B on the insert; see fig. 8
and 9. Place the insert in the connection box and connect wires A to the heating
element. Make sure that bushing D is correctly positioned. Fit the cover, so that
the round part covers the hole previously used for the connection cable.
When using a backing washer, the connection box must be raised about 1 mm
above the backing washer to allow the lid to be fitted; see fig. 10. Slacken the
screws a little on the nearest wall bracket and pull the towelwarmer from the
wall. Fit the cover and push the connection box into the backing washer; see fig.
10 and 11. Screw the cover and the wall bracket securely in place.
Fix the enclosed instruction sticker (on the back of this manual) to the
connector housing in a readable place for the user, and position it so
that the knob (in O position) is consistent with the image (at the stand-
ard connection above the knob and the concealed connection in front
of the knob).
oPeratIon
The towelwarmer is in all-pole disconnect mode when the switch is in
O-position. The towelwarmer can be in constant operation without any risk. The
temperature of the pipes may vary.
For the Nila R and Muria R models, the surface temperature is adjustable
between ca. 38ºC and 60ºC. Chose a temperature by turning the knob clockwise
for higher temperature.
Nila Ti and Muria Ti: The operating time is continuously adjustable from 2 to 8
hours. You can also choose to have the heating on continuously. For continuous
heating: Turn the knob to the end position ∞. The lamp lights with a fixed beam.
For timer setting: Turn the knob to the desired time period and activate by press-
ing the triangle button/lamp. This confirms through flashing before switching
to a fixed beam during the set time. The heating can always be restarted at any
time by pressing the button again (confirmed by a flashing light). To stop the
heating, the knob must be in position O for about 10 seconds (to handle short
power failures).
This appliance is intended only for drying textile material washed in water.
care
Use only mild cleaning agents when cleaning and wiping of the towelwarmer is
necessary.
cautIon
If the instructions for fitting and use are not followed, this may lead to overheat-
ing and malfunction.
The connection cable to this appliance is a special type. If it is damaged and
must be replaced, it must be ordered and replaced by the manufacturer or its
representative, or person with equivalent qualifications, in order to avoid any
danger.
The maximum surface temperature that can be reached by an exposed surface
is 60°C.
This towelwarmer is filled with a precise quantity of liquid, and any repairs that
involve opening the towelwarmer must be carried out by the manufacturer or
his service representative. Any leakage must be dealt with by the manufacturer
or his representative.
The liquid in the towelwarmer is not frost sensitive.
This appliance is not intended for use by children or by people with impaired
mental ability, or who lack knowledge or experience, unless they have been
instructed in the use of the appliance by a person responsible for their safety.
Children should be supervised to ensure they do not play with the appliance.
warranty
The warranty is valid for 10 years except for electrical components which
is valid for 2 years. In the event of any problems or repairs, please contact your
supplier.