Values:
EN
- Lock-release activation time:
- Exit button:
activated/deactivated, (selected via the web server). By default it is active.
-
Conversation time: 90 secs
- Door sensor
time: 01..99, (by default: 00, not active).
-
Panel type: The Lynx amplifier module detects the connected modules, so the system
knows if the panel is digital (display + keypad), a push button or 1 Line.
-Default panels' IP addresses:
•
Digital Panel: 10.200.100.0
•
Push button panel: 10.200.0.0
-
Types of Configuration:
•
Digital Panel: General Entrance or Block
•
Push button panel: only Block
Capacities:
•
Number of Panels:
- General entrances: 100 (00...99).
- Blocks: 100
-
1L Panels:
* Private Residence Panel: 8 (00...07).
* Emergency Panel: 255 (000...254).
Streaming:
By enabling this function, the A&V module (amplifier), provides a video streaming that
allows you to connect via the standard RTSP, and works to record the conversation via
a recorder.
Available in panels with version V3.1 or greater.
The streaming service allows for a maximum of 5 simultaneous clients.
Stream technical data:
• The stream uses the standard RTSP.
• The resolution is VGA (video Lynx).
• Frame rate is 25 fps.
• Video codec H-264.
• Audio codecs G-711A, G-726.
The streaming option is enabled via the server that incorporates the panel, in
ADVANCED SETTINGS/Audio & Video/DVR. For more details see the 970020 Web
server manual for Lynx Panels at www.fermax.com.
Note: The Technical Characteristics and Values specific to the Digital Panel are defined in
their corresponding manuals , (all available at www.fermax.com):
•
970015 Digital Lynx Programming Manual
•
970019 Skyline Lynx Display Manual
•
970020
Lynx Panels Web Server Manual
Pag 22
01..99 sec. (Default: 05).
(General Entrance - Panel: 0)
(00...99).
(Block:0 - Panel:0)
.